Datasheet
VAV
PMAFIX
Connector
45° elbow IP68 metric thread
DB-Nr. 22022-04 19.02.2010/YS Technical Data Sheet Technisches Datenblatt 2/2
Verschraubung
45° Winkel IP68 metrisches Gewinde
PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch
The specifications and instructions for our customers in this document reflect the product engineering
level at the time of manufacturing. Please consider the valid data sheet release at a time. For questions
please contact the PMA customer service. PMA AG accepts no liability for damages resulting from un-
professional installation or application or misuse for a purpose. This disclaimer also includes damages
to third parties. It is the customer‘s responsibility to check the delivered products and immediately
notify PMA AG of detected faults. It is also the customer‘s responsibility to test the delivered product
on its applicability for the intended purpose. PMA AG will accept no liability or responsibility for their
products if a product or a PMA system is combined or used together with third-party products, i.e.
products from other companies than PMA AG. Jurisdiction in all legal disputes concerning product
liability have the courts of the canton of Zurich/Switzerland. Swiss law applies.
For more information and the newest data sheet releases go to: www.pma.ch
Die in diesem Dokument für unsere Kunden enthaltenen Angaben und Instruktionen entsprechen dem
neuesten Stand unserer Technik zum Zeitpunkt der Herstellung des Produktes. Es ist der jeweils gültige
Datenblattstand zu berücksichtigen. Bei Fragen wenden Sie sich bitte an den PMA-Kundendienst. Die
PMA AG lehnt jede Haftung bei unsachgemässer Montage oder Verwendung sowie Zweckentfrem-
dung des Produktes ab. Dieser Haftungsausschluss umfasst auch allfällige Drittschäden. Es obliegt dem
Kunden, die gelieferte Ware zu prüfen und allfällig festgestellte Mängel sofort der PMA AG anzuzeigen.
Es obliegt ferner dem Kunden, die Ware auf ihre Eignung zwecks einer spezifi schen Anwendung zu
überprüfen. Die PMA AG lehnt jegliche Haftung für ihre Produkte ab, wenn ein einzelnes Produkt oder
ein PMA-System mit Fremdprodukten, d.h. Produkten anderer Unternehmungen kombiniert bzw. ver-
wendet wird. Gerichtsstand für Streitigkeiten bezüglich Produkthaftung sind die Gerichte des Kantons
Zürich/Schweiz. Es kommt Schweizer Recht zur Anwendung.
Ergänzende Informationen und neueste Datenblätter unter: www.pma.ch
CABLE PROTECTION
KABELSCHUTZTECHNIK
properties unit value test method
Eigenschaften Einheit Wert Prüfmethode
Mechanical properties Mechanische Eigenschaften
Tensile modulus Zug-E-Modul
N/mm2 1‘200 ... 3‘700 ISO 527
Tensile strength Reissfestigkeit
N/mm2 45 ... 65 ISO 527
Notched bar impact test Kerbschlagzähigkeit
kJ/m2 4 ... 20 ISO 180/1C
Thermal properties Thermische Eigenschaften
Temperature range Temperaturbereich °C
– 40 ...+ 105 PMA DO 9.21-4510
Short-term Kurzzeitig °C
+ 160
Fire safety characteristics Brandschutzeigenschaften
Free from halogens and cadmium Halogen- und cadmiumfrei yes ja
DIN 53474
Flame class Flammklasse V0
UL 94
Glowing wire test Glühdrahtprüfung °C 960
EN 60695-2-10
Fire protection category Brandschutzkategorie Cat. II, int. / ext.
BS 6853
Fire protection category Brandschutzkategorie HL3 int. / ext.
CEN/TS 45545-2
Oxygen index (LOI) Sauerstoffi ndex (LOI) % > 35
EN ISO 4589-2
I-classification I-Klassifi zierung I3
NF F 16-101 / 102
Smoke emission class Rauchgasklassifi zierung F2
NF F 16-101 / 102
Fire protection grades (LOI) Brandschutzstufen (LOI) > 30
fulfilled/erfüllt DIN 5510-2:2009 (5.2.2.4)
Fire risk level Brand-Risikostufe LR4
UNI CEI 11170-3 Ed. 2005
Fire performance Brandverhalten s 30
EN ISO 11925-2
Chemical properties Chemische Eigenschaften
Please refer to catalogue ersichtlich in PMAFIX/PMAFLEX-
PMAFIX/PMAFLEX or
www.pma.ch Katalog oder unter www.pma.ch
System test Systemprüfung
Ingress protection: Dichtheit:
System V with SVN4 and NVN3 System V mit SVN4 und NVN3 IP68 40m depth
/ Wassertiefe EN 60529 / IEC 60529 /
(5 bar) > 30min PMA DO 9.21-4100
IP69K
DIN 40050
incl. water impact protection WPS inkl. Wasserprallschutz WPS IP69K (100 bar)
DIN 40050 / PMA DO 9.21-4100
Application approvals Anwendungszulassungen
CSA CSA CSA C22.2 Nr. 227.3
certification authority
Underwriters Laboratories Underwriters Laboratories RU recognised comp. / UL 1696
certification authority
SEV SEV CE
(IEC 61386 low voltage directive) accredited laboratory
Content of delivery Lieferumfang
Connector with clip (OVN2), Verschraubung mit Sperre (OVN2),
Thread gasket (SVN4), Gewindefl achdichtung (SVN4),
Conduit seal (NVN3) Rohrdichtung (NVN3)
Mounting indication Montagehinweis
Please consider the appropriate Bitte beachten Sie die entsprechende
assembly instructions on www.pma.ch Montageanleitung unter www.pma.ch