59!of!159!
!
3.2.3 Load Cell
Figure 45: Load cell.
This single-axis load cell is particularly suitable for handgrip, traction/compression, and
similar applications. Its sturdy design and accessories enable force measurement in many
different settings. The plug & play design provides maximum flexibility for use with our
biosignal acquisition kits.
How to connect your sensor to your biosignalsplux
The load cell can be connected to any of the available analog inputs of your biosignalsplux
device (see 2.3.2 Analog Inputs).
This sensor does not require an additional reference electrode.
How to configure your sensor in OpenSignals (r)evolution
Open the OpenSignals (r)evolution device manager and select the device you have your
load cell connected to. Select the channel of your load cell and select HANDGR from the
dropdown menu (click on the arrow in the channel’s field that appears when you hover
over the channel’s field).
Activate the respiration sensor’s channel for signal acquisition by clicking on the circle in
the channel field (must be blue).
An example configuration is displayed in Figure 46 (here: load cell connected to channel
1).