Specifications
8
not recede, if it goes up, or if air enters the transparent air
check chamber and the ball falls and seats, refer to the
Troubleshooting section in this manual.
5. When water is being drawn from the brine tank, press
down on the drive gear and rotate the cam gear
counterclockwise to just before the Service position,
Figure 10. Connect power to the control and allow the
motor to drive the cam gear to the Service position, the
motor will stop. Run cold water from a nearby faucet
until the water is clear and soft.
Figure 10
Battery Back-Up Feature
The Technetic Plus 1100 is supplied with a battery operation
feature allowing the control to continue to monitor water flow
and maintain the proper time of day during short power
outages. The control uses a standard 9-volt battery (not
supplied).
During a power outage, the display will be turned off and the
motor will not run, but the control will continue to totalize
water flow. If power is out and a regeneration is needed, the
regeneration will be delayed until power is restored. If power
is lost during a regeneration, the control will resume the
regeneration when power is restored.
A typical new 9-volt alkaline battery will provide
approximately two days of power for the control. Older
batteries or those exposed to temperatures over
75
o
F (23.9
o
C) will provide power for a shorter length of time.
The control can be operated without a battery, but the control
will not measure water usage or time while the power is off.
The control will save all important operating information and
programming data during a power outage. No
reprogramming is necessary.
Note: It is recommended that the battery be replaced every
year or after any extended power outage.
To install a battery:
1. Remove the cover of the Technetic Plus 1100.
2. The battery pocket is located in the upper left corner of
the control.
3. The battery connector has special snaps which allow the
battery to be installed properly. Press the new battery
firmly into the snaps.
4. Place the battery into the pocket.
5. Replace the valve cover.
Air Check