Specifications
www.Technetic Plus.com
15. Intermittent or irregular
brine draw.
a. Low water pressure.
b. Defective injector.
a. Increase water pressure (20 psi at
conditioner).
b. Replace both injector and injector cap.
16. No conditioned water after
regeneration.
a. Unit did not regenerate.
b. No salt in brine tank.
c. Plugged injector.
d. Air check valve closed prematurely.
e. Incorrect salt type or use of grid plate
(salt shelf) in brine tank.
a. Check for power.
b. Add salt to brine tank.
c. Remove injector and flush it and injector
screen.
d. Put control momentarily into REFILL to free
air check. Replace or repair air check if
needed. Refer to instructions.
e. Do not use block salt or grid plate (salt shelf)
in brine tank.
17. Control backwashes at
excessively low or high rate.
a. Incorrect backwash controller.
b. Foreign matter affecting controller
operation.
a. Replace with correct size controller.
b. Remove and clean controller.
18. Flowing or dripping water at
drain line or brine line after
regeneration.
a. Drain valve (2 or 6) or brine valve (1)
held open by foreign matter.
b. Weak valve stem return spring on top
plate.
c. Resin in valve.
a. Manually operate cam gear to flush out
foreign matter holding disc open.
b. Replace spring.
c. Clean valve and backwash control.
19. Hard water leakage during
service.
a. Improper regeneration.
b. Leaking of bypass valve.
c. O-ring around riser tube damaged.
d. Incorrect salt type or use of grid plate
(salt shelf) in brine tank.
a. Repeat regeneration making sure that the
correct salt dosage is used.
b. Replace O-ring.
c. Replace O-ring.
d. Do not use block salt or grid plate (salt shelf)
in brine tank.
Table 7 - Troubleshooting Procedures