Specifications

27
10. Control does not regenerate
automatically or when
REGEN button is depressed.
a. Transformer unplugged.
b. No electric power at outlet.
c. Defective motor.
d. Defective switch.
a. Connect power.
b. Repair outlet or use working outlet.
c. Replace motor assembly.
d. Replace switch.
11. Control does not regenerate
automatically but does
regenerate when REGEN
button is depressed.
a. If water flow display is not operative,
refer to item 5 in this table.
b. Incorrect hardness and capacity
settings.
c. Defective circuit board.
a. Refer to item 5 in this table.
b. Set new control values. Refer to the
Programming section.
c. Replace control.
12. Run out of soft water
between regenerations.
a. Improper regeneration.
b. Fouled resin bed.
c. Incorrect salt setting.
d. Incorrect hardness or capacity settings.
e. Water hardness has increased.
f. Restricted meter turbine rotation due to
foreign material in meter housing.
g. Water usage below 1/5 gallon per
minute.
h. Brine draw value from Table 4 is
incorrect.
i. Incorrect salt type, or use of grid plate
(salt shelf).
a. Repeat regeneration making certain that
correct salt dosage is used.
b. Use resin cleaner.
c. Set salt setting to proper level. Refer to the
Programming section in this manual.
d. Set to correct values. Refer to the
Programming section of this manual.
e. Set to new value. Refer to the Programming
section of this manual.
f. Remove meter housing, free up turbine, and
flush with clean water. Turbine should spin
freely, if not, replace meter.
g. Repair leaky plumbing and/or fixtures.
h. Set correct brine draw value.
i. Do not use block salt or grid plate (salt shelf)
in brine tank.
13. Control does not draw brine
a. Low water pressure.
b. Restricted drain line.
c. Injector or injector screen plugged.
d. Injector defective.
e. Valve disc 3 and/or 5 not closed.
f. Air check valve prematurely closed.
a. Increase water pressure (20 psi at
conditioner).
b. Remove obstruction.
c. Clean injector and screen. Refer to the
Cleaning the Injector/Injector Screen section
in this manual.
d. Replace injector and cap.
e. Manually operate cam gear to flush out
foreign matter holding disc open. Replace if
needed.
f. Briefly put control into brine refill status.
Refer to the Manual Regeneration section in
this manual. Replace or repair air check valve
if needed.
14. Brine tank overflow.
a. Brine valve disc 1 held open.
b. Valve disc 2 not closed during brine
draw, causing brine refill.
c. Air leak in brine line to air check.
d. Salt setting too high.
a. Manually operate cam gear to flush out
foreign matter holding disc open.
b. Manually operate cam gear to flush out
foreign matter holding disc open.
c. Check all connections in brine line for leaks.
d. Set in new values. Refer to Programming
section in this manual.
Problem Possible Cause Solution
Table 7 - Troubleshooting Procedures