Specifications

14
Level II Parameters
The programming in Level II is critical to the
operation of the Technetic Plus 1100 Control.
Refill control value P6, brine draw value P7, and slow rinse
time P10 must be programmed according to conditioner
system size using Table 4. Other programming parameters in
Level II can be used to increase the efficiency of the water
conditioning system.
The Operating and Maintenance Manual for this product does
not mention these parameters, so the end user does not
normally have access to these values. To access Level II
Parameters, simultaneously press and hold the down arrow (
) and up arrow ( ) button for three seconds.
If the control was alternating between Time of Day and
Capacity when the above button sequence is entered, the
display shows P1. If a different Level I Parameter was
displayed, the display shows the “P” number for that
parameter. Refer to Table 3 to find the “P” number associated
with each parameter.
Use the up arrow ( ) button or the down arrow ( ) button
to move from one parameter to the next. The display cycles
through the ”P” numbers shown in Tables 1 and 3. When you
reach P19, the display will go back to P1.
When the parameter number you want to change is displayed,
press the left arrow ( ) button to display the data assigned
to that parameter. Press the SET button and the far right digit
on the display starts flashing. If you want to change this
number, press the up arrow ( ) button or the down arrow (
) button. To skip the number without changing, press the
left arrow button. When the number is correct, press the SET
button. The numbers stop flashing and the control accepts the
new setting. If the new setting was not accepted, the display
will show the previous setting. Refer to Table 3 for allowable
values for that parameter.
To change or view other parameters, press the left arrow (
) button to have the display show “P” numbers. Now use the
up arrow ( ) button or the down arrow ( ) button to move
to the parameter number you wish to change.
To exit the Level II programming mode, simultaneously press
and hold the down arrow ( ) and up arrow ( ) buttons for
three seconds, or wait 30 seconds, without pressing a button.
The control starts alternating the display between Time of
Day and Capacity.
Table 4 - Technetic Plus System Sizes
Tank Sizes Resin Volume
Refill
Controller
Brine Draw
Value
Slow Rinse
Time
Inches Metric Ft
3
Liters
7x35 18x89 0.50 15 14 9 67
7x40 18x101 0.50 15 14 9 67
8x40 21x101 0.75 21 14 7 83
8x44 21x112 0.75 21 14 7 83
9x35 23x89 0.75 21 33 9 70
9x48 23x122 1.00 28 33 9 94
10x35 26x89 1.00 28 33 15 53
10x44 26x112 1.25 35 33 15 67
10x47 26x119 1.25 35 33 15 67
10x54 26x137 1.50 44 33 15 80
12x48 30x122 2.00 56 33 16 83
12x52 30x132 2.25 64 33 16 94
13x54 33x137 2.50 71 33 18 107
14x47 35x119 2.50 71 33 21 60
14x65 35x165 3.00 85 33 21 72
14x65 35x165 3.25 91 33 21 78
14x65 35x165 3.50 99 33 21 84