Specifications

13
Table 3 - Level II Programming Parameters
Parameter Range of
Values
Minimum
Increments
Default
Units of
Measure
Notes
Name Description
P6
Refill
Controller
1 to 99 1 33
Select value from Table 4 and enter that
number.
P7
Brine draw
value
1 to 99 1 25
Select Brine Draw value from Table 4 and
enter that number.
P8 Not used N/A N/A N/A N/A N/A
P9 Backwash time 3 to 30 1 14 Minutes
Skip this parameter to accept the default
or enter a value.
P10
Slow Rinse
time
8 to 125 1 40 Minutes
Select Time from Table 4 and enter that
value.
P11 Fast Rinse time 2 to 19 1 4 Minutes
Skip this parameter to accept the default
or enter a value.
P12
Units of
measure
0 to1 1 0
0 = U.S., 1 = metric. Skip this parameter
to accept U.S. or enter
1 for metric.
P13 Clock mode 0 to 1 1 0
0 = 12-hour clock, 1 = 24-hour clock.
Skip this parameter for a 12-hour clock or
enter 1 for a 24-hour clock.
P14
Calendar
override
0 to 30 1 0 Days
0 = no calendar override. Skip this
parameter for no calendar override or
enter a value.
P15 Reserve type 0 to 3 1 0
0 = variable reserve, 1 = fixed reserve, 2 =
variable reserve with immediate regen, 3
= fixed reserve with immediate regen.
Skip this parameter to accept the default
or enter a different reserve type.
P16
Fixed reserve
capacity or
initial average
value
0 to 70 1 30
Percent of
capacity
Description depends on the value entered
for P15. Skip this parameter to accept the
default or enter a different value.
P17 Operation type 0 to 1 1 1
0 = Not used, 1 = 5 cycle counter current,
partial salting.
P18
Salt/Capacity
change lock
out
0 to 1 1 0
0 = none, 1 = salt/capacity change locked
out. Skip this parameter to accept the
default or enter 1 to lock out salt/capacity
change.
P19
Factory
defaults
0 to 3 1 9
Loads in factory default values.
Do not change this parameter.