Use and Care Manual
Special Attention for situations where a Filter and a Softener are installed
together:
When a whole house filter and a softener are installed side by side, the only approach is to run a
separate drain line from each unit all the way to the point of termination. If this is not done, there is
the potential for drain water from the filter to back feed through the softener and overfill the brine
tank, especially when drain lines are run overhead. (Please note that back feed goes only into the
brine tank, not the service line.)
If circumstances require you to tie the drain lines together, please use the following method to avoid
back feed issues:
Run the drain lines from both systems to the point of termination, and tee them together before the
air gap. (See figures below)
8
WATER I
N
TREATED
WATER OUT
2 SEPARATE DRAIN LINES
TO APPROVED DRAIN
LOCATION WITH AI
R GAP
FILTER
SOFTENER
2 SEPARATE
DRAIN LINES
AIR GAP
APPROVED FLOOR DRAIN
TEE
*
* Hard drain line piping shown on the drawing.