Congratulations on your purchase of a high quality water treatment system.
SYSTEM INFORMATION
POWER REQUIREMENTS
The computer board receives power from an external wall-mount transformer, supplied with each
system.
Voltage: The voltage supplied to the computer board is 24V AC.
Frequency: The line frequency is 50 Hz or 60 Hz.
WATER PRESSURE
A minimum of 20 Psi of water pressure is required for proper operation of the system. The stated oper-
ating pressure range is 20 psi - 120 psi (138 kPa - 828 kPa).
BYPASS VALVE
The bypass valve enables the customer to bypass the system in situations of: emergency leaks in the
equipment, service calls and/or outdoor water use.
TEMPERATURE OPERATING RANGES
Operating Temperature Range: 40° F - 100° F (4.4° C - 38° C)
Storage Range: The computer board can be stored at temperatures from -20°C (-4°F) to 70°C (158°F).
Humidity: The computer board operates properly with relative humidity from 10% to 95%, non-
condensing.
ENVIRONMENTAL REQUIREMENTS
Location: The water softener and control cannot be exposed to outdoor elements, such as direct
sunlight or atmospheric precipitation. The system may be installed in a covered, open-air structure
such as a carport, residential or commercial building.
OPERATIONAL SPECIFICATIONS
OPERATIONAL SPECIFICATIONS
THE ORDER NUMBER FOR THE REPLACEMENT MEDIA IS 39339*
Also includes gravel underbedding.
UNIT SIZE
SYSTEM PART
NUMBER
MODEL
SERVICE FLOW
RATE
(GAL/MIN)
PSI DROP AT
SERVICE FLOW
RATE
DRAIN FLOW
RATE
(GAL/MIN)
SALT PER
REGENERATION
(LBS)
CAPACITY AT
LOW SALT
SETTING(GRAINS)
CAPACITY AT
MEDIUM SALT
SETTING(GRAIN
S)
CAPACITY AT
HIGH SALT
SETTING(GRAIN
S)
EFFICIENCY
(GRAINS/LB. OF
SALT)
1.0
35594
WATER
SOFTENER 1.0
11.6 12 2.5 3.9 - 15.6 17500 25200 33500 4487