Use and Care Manual

14
UNDERSTANDING THE DIAGNOSTIC LEVEL
To begin, verify that the control is in the Service Mode.
Press the UP ARROW and hold it for 5 seconds; the control will display:
The control is now in the Diagnostic Level. Use the SCROLL BUTTON to advance to each diagnostic.
If no button is pressed within 5 minutes, the display will return to the Service Mode.
The following items are available in the Diagnostic Level (Read Only):
Regen _ Days Ago: Displays how many days ago the unit last regenerated.
In Srvc: Displays how many days the control has been in service.
# of Regens: Displays the number of regenerations that have taken place since the control was first
installed.
Tot Vol: Displays the total volume of water used since installation.
Last Rgn @: Displays the amount of water used before the last regeneration.
Flow Rate: Displays the current flow rate.
Avg Vol: Displays the average daily water consumption.
Water Hard: Displays the amount of hardness programmed into the control.
Rsrv: Displays whether the control is programmed for a Fixed or Variable Reserve.
Regen @: Displays the time of day the unit will regenerate.
Override: Displays the override mode by reading “OFF” or the number of days programmed into the
control.
Backwash: Displays the minutes of backwash programmed into the control.
BRN/RNS: Displays the minutes of brine and slow rinse programmed into the control.
FILL/RNS: Displays the minutes of fast rinse and brine refill programmed into the control. This is
calculated based on unit size and salt level, and is not settable by the user.
Units: English - US
Salt Level: Displays the amount of salt ( Low, Medium, or High) for regeneration.
M P Resets: Displays how many times the control has lost power.
Memory Reset: Displays how many times the control lost power long enough to lose the time of day.
SP1Sc PlumbR20: Displays the current program.
To exit the Diagnostic Level, press the DOWN ARROW at the EXIT display.
Time of Day GL Remaining
Regen _ Days Ago