Use and Care Manual

Press the SCROLL BUTTON to advance to the next setting.
5. CYCLE 1 - BACKWASH
The control will display:
6. CYCLE 2 - BRINE/SLOW RINSE
The control will display:
Press the Up or Down ARROW to change the length of the brine/slow rinse cycle. The minimum length is pres-
elected based on unit size and salt level, and cannot be reduced. The maximum setting is 99 minutes.
Press Down Arrow to exit Installer’s Mode.
MPORTANT NOTE: TO ACTIVATE THE NEW SETTINGS, YOU MUST EXECUTE A COMPLETE REGENERA-
TION. IF YOU DO NOT MANUALLY REGENERATE THE SYSTEM, THE SETTINGS WILL NOT BECOME
ACTIVE UNTIL THE UNIT HAS COMPLETED THE NEXT SCHEDULED REGENERATION.
HOW TO PROGRAM THE END USER’S LEVEL
To began, verify that the control is in the Service Mode:
Press the SCROLL BUTTON to advance to the next setting.
The following settings are available in the End User’s Level:
1. TIME OF DAY
The control will display:
Press the UP or DOWN ARROW to program the time of day.
Press the SCROLL BUTTON to advance to the next setting.
2. IMMEDIATE REGENERATION MODE
The control will display:
If the control is left in this position, the timer will countdown from 10 to 0, initiating a regeneration at 0.
To avoid an immediate regeneration, press the SCROLL BUTTON before the timer reaches 0.
Press the SCROLL BUTTON to advance to the next setting.
3. DELAYED REGENERATION MODE
The control will display:
If the control is left in this position, the unit will regenerate at the programmed time. The display will
remain in the Delayed Regeneration Mode until the regeneration has begun.
To cancel the Delayed Regeneration Mode, press the SCROLL BUTTON.
Press the SCROLL BUTTON to return to the Service Mode.
13
Backwash: 10 min
BRN/RNS: 74 min
Time of Day GL Remaining
Set Time of Day
Regen in 10 sec
To Exit Press Down Arrow
Regen @ (2.00 am)