User's Manual

6 7
Removing Sense
If the Sense will (temporarily) no longer be used, it can be removed from
the Plugwise network.
Ì Start Source and go to Sengs, Devices.
Ì The list of ‘Non-assigned modulesis displayed to the right of the
screen. Right-click the Sense and then clickDelete’.
Ì The Sense will now be ignored by the network.
Ì To also physically remove the Sense from the ceiling, follow the steps
as described in secon 2, Aaching the Sense to the wall’, in reverse
order.
Ì Note: remove the baery. As long as the Sense is not assigned to a
network, it will consume more power and the baery will drain more
quickly.
4.  Advanced use
Connecng Sense to another network
Aer a Sense has been removed from a network (see the explanaon
above), it can be connected to another Plugwise system. To do this,
follow the normal installaon procedure.
Restarng Sense
In case of problems, the Sense can be restarted. For this purpose, a reset
buon can be found on the back of the module, which can be acvated
by inserng a long, thin object such as a pin or a paperclip (not a pencil
or mechanical pencil, which can break o) in the hole marked Reset’.
When the LED light in the casing (on the front of the module) begins to
ash, the Sense has restarted.
Deleng network sengs
You can also delete all of the sengs saved on the Sense. As a result,
the Sense will also forget its posion in the network. To delete all of the
sengs, follow the instrucons as described in the secon ‘Restarng
Sense, but keep the reset buon pressed unl the rapidashing of the
LED light stops. This should take about 10 seconds.
Firmware updates
When a new rmware version is available, the update can be
downloaded and sent to the Sense. More informaon on rmware
updates is provided in the Source manual. Aer you send thermware
update from Source, press the white wake buon on the top of the
front of the Sense. The Sense will then waken temporarily to receive
and install thermware update.
5.  Technical details
Specicaons
Parameters Min. Nominal Max. Unit Comments
Environment
Operaonal
0
5
60
95
˚C
%RH
No condensaon
Storage
10
20
50
60
˚C
%RH
No condensaon
Temperature measurement
Measurement range 0 60 ˚C
Measurement accuracy
± 0.8 ± 0.3 ˚C
Within a range of 0˚C to
60˚C
± 0.6 ˚C At 0˚C
± 0.3 ˚C At 25˚C
± 0.8 ˚C At 60˚C
Air humidity measurement
Measurement range 5 95 %RH
Measurement accuracy
± 3.5 ± 2.0 %RH
Within a range of 5%RH to
95%RH
± 3.2 %RH At 5%RH and at 95%RH
± 2.2 %RH
Between 10%RH and
90%RH
Power supply
Supply voltage 3.2 3.6 3.6 Vdc A single 3.6V AA baery
Baery life 1 2 year
Based on 1 rmware update
per year, a maintenance
interval of 24 hours and 1
transmission of measurement
data per 15 minutes
Power consumpon 150 mW
Dimensions 86 x 80 x 21 mm Height x width x depth
Memory
Storage capacity 512 kByte
Used for ZigBee rmware
updates
Service life 100,000 Cycles Programming/deleng
ZigBee communicae
Baud rate 250 kbps O-QPSK
Frequency 2400 MHz
16 channels of the 2,4GHz
ISM band
Bandwidth 2.0 MHz 5 MHz channel space
Recepon sensivity -92 -97 -98 dBm @ 1% per 20-byte packet
Transmission power -32 3 5 dBm
LED
When the Sense sends data wirelessly via the Plugwise ZigBee protocol,
a red LED light starts toash in the casing.