Installation Instructions

7077-801D • September 17, 2019
customerservice@ghpgroupinc.com
9
B. User Dial Control
The appliance has one dial control located on the side of
the unit used for daily operation.
There are four primary
settings on this dial.
O󰀨:
- When the dial indicator is in the o󰀨 position the unit
will go into a shut down and remain o󰀨 until the dial
is turned to one of the other three settings. The
LED will ash green once per second when in the
o󰀨 position.
MIN:
- When the dial indicator is directed to the MIN
setting (small ame on the label) the unit will burn
on low until the hopper runs out of pellets or the
dial control is turned to a di󰀨erent setting. When
in this setting the LED will be amber in color and
continuously on. When burning in this mode, the
unit should be turned o󰀨 at least once daily for
cleaning. If lower quality fuels are used, additional
daily shut downs may be required for cleaning.
MAX:
- Similar to the MIN mode, the unit will run
continuously at the high burn rate until the unit has
run out of fuel or the dial is turned to a di󰀨erent
setting. To operate in this mode, turn the dial
clockwise until it stops. The dial indicator will point
to the large ame. When in this setting the LED will
be amber in color and continuously on. Follow the
daily cleaning recommendations when operating in
this mode. If lower quality fuels are used, additional
daily shut downs may be required for cleaning.
AUTO:
- To burn in the Automatic mode, turn the dial
control clockwise to the desired comfort level.
When operating in the automatic mode, the unit
changes the burn setting based on the di󰀨erence
between the room temperature and the desired
set point. In other words, the unit will burn on High
if the di󰀨erence between the desired and room
temperature is greater than 8 degrees Fahrenheit.
As the room heats up and the gap closes, the unit
will automatically reduce the burn rate. When the
room temperature is close to the set point the light
will stop ashing stay solid green. At this time the
stove will be burning on the lowest burn rate. When
the desired temperature is achieved the unit will
shut down. As the room cools, the unit will restart
automatically. When burning in this mode the LED
will be blinking green. The number of green ashes
corresponds to the current burn rate.
C. Filling the Hopper
Slowly open the hopper lid by lifting the handle. The
medium and large units have a locking latch that will
engage when the hopper lid is fully opened. The hopper lid
for the cabinet will open past ninety degrees and stay open
automatically. Fill the hopper with fuel. FOR USE WITH
ONLY WOOD PELLET FUEL. Slowly close the hopper lid.
See gure below for releasing the latch.
0
-
1
-
2
-
3
-
4
+
1
+
2
+
3
+
4
A
U
T
O
M
A
T
I
C
/
A
U
T
O
M
Á
T
I
C
O
/
A
U
T
O
M
A
T
I
Q
U
E
O
F
F
M
A
X
M
I
N
O
N
A
U
T
O
A
L
A
R
M
Push Bottom of Latch
Inward to Release
NOTE: The unit will not feed with the hopper lid open. If
left open, the re will go out.