Installation Instructions

7077-801D • September 17, 2019
customerservice@ghpgroupinc.com
5
A.
Appliance Certication
NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM
E1509-04, ULC S627-00, (UM) 84-HUD,
Series:
PH35PS-B, PH50PS-B,
PH50CABPS-B
Safety Laboratory: UL LLC
Safety Report No. MH60687
Type:
Solid Fuel Room Heater/Pellet Fuel
Burning Type
Standard:
ASTM E1509-04 and ULC S627-
00, Room Heater Pellet Fuel
Burning type and (UM) 84-HUD,
Mobile Home Approved.
This pellet heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this
pellet heater in a manner inconsistent with operating instructions in this manual.
PH35PS-B
PH50PS-B
PH50CABPS-B
Emissions
Report No:
0061PS095E 19-470
Emissions
Laboratory:
OMNI PFS-TECO
EPA
Certication
No:
Number: N.A. Number: N.A.
EPA Certied
Emissions:
0.7 g/hr 1.2 g/hr
*LHV Tested
E󰀩ciency:
79.4% 81.1%
**HHV Tested
E󰀩ciency:
74.6% 75.9%
***EPA BTU
Output:
6,800 to 26,000 /hr 6,900 to 34,100 /hr
****BTU
Input:
9,600 to 33,200 /hr 9,800 to 44,400 /hr
Vent Size: 3 or 4 inches, “L” or “PL”
Hopper
Capacity:
40 lbs. 80/120 lbs.
Fuel Premium Wood Pellets
* Weighted average LHV e󰀩ciency using data collected
during EPA emissions test.
**Weighted average HHV e󰀩ciency using data collected
during EPA emissions test.
***A range of BTU outputs based on EPA Default
E󰀩ciency and the burn rates from the low and high
EPA tests.
****Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
B. BTU & E󰀩ciency Specications
1 Listing and Code Approvals
The PH35PS-B, PH50PS-B &
PH50CABPS-B is Certied to
comply with 2020 particulate
emission standards.