Manual

21
Measurement
Technology
Time Domain Reectometry (TDR)
Cable
Measurements
Cable Testing and ID: up to 1000 ft (305 m)
Split Pair Detection: 3 ft (1 m) to 1,000 ft (305 m)
Length Measurement: 0 to 1,500 ft (457 m), ± (5%+1ft)
Supports 8 continuity and ID number remotes (RJ-45)
Supports 20 RJ-45 and 20 F-Connector ID only remotes
Power over
Ethernet
Tests for IEEE 802.3af and IEEE 802.3at (PoE Plus)
compliant PoE
Tests for classes and loads cable up to 25.5 watts
(at class 4) Identies Mode A or B (pairs with PoE)
Active Ethernet
Indicates advertised speeds of 10/100/1000base-t half
or full duplex
Can Link to network at 10/100base-t
Maximum Voltage
Parameters refer to the maximum voltage that can be
applied to any 2 connector pins without causing damage
to the tester.
• RJ Jack: 66 VDC or 55 VAC
• F-connector: 50 VDC or VAC
Save Test Results
Stores up to 256 Cable or network tests with user
dened names
Tone Generation Tone Frequencies: 730 Hz and 1440 Hz
Languages English, French, Spanish
Battery Life
For 6 x AA, 9 VDC, 2,200 mA-hr (typical) alkaline battery:
Operating – 20 hours typical
Standby – 1.5 years typical
(200uA max standby current)
Batteries are included
Altitude 10,000 ft (3048 m) operating
Temperature
Operating: 32 to 122°F (0 to 50°C)
Storage: -22 to +140°F (-30 to 60°C)
Humidity 10 to 90% non-condensing
Enclosure
High-strength PC/ABS plastic with V0 rating with boot
Withstands 4 foot drop on to concrete
Size 1.85”H x 3.6”W x 6.8”L (4.7 x 9.15 x 17.3 cm)
Weight With batteries: 1 lb 2 oz (510 g)
Safety
Compliances
CW
Warranty 1 Year