Manual
11
Changing a Setting
▪ RJ45 VoP : Set the VoP to be used to measure RJ45 cable.
▪ Coaxial VoP
: Set the VoP to be used to measure coaxial
cable.
▪ TIA568A/TIA568B: Set the RJ45 wiring conguration to
TIA568A or TIA568B wiring standard.
▪ Pair/Pin: Set the RJ45 wiremap to measure by pair or pin.
▪ Meters/Feet
: Set the length measurement to be displayed in
Meters or Feet.
▪ Pair/Pin can be changed to test the RJ45 from Wire Order to
Pair Order.
▪ Power Off Timeout
: Set the desired automatic timeout from
00.5-99.9 minutes.
▪ LCD Dimmer Timeout
: Set the desired automatic timeout from
00.5-99.9 minutes.
▪ Language: Set the desired language from English (default) to
Spanish or French.
▪ Tone Generator Timeout: Set the desired automatic timeout
00.5-99.9 minutes.
▪ PoE Test: Turn the PoE test On or Off. Turning the PoE off
will allow the Cable Prowler to detect a network without
running a PoE test.
▪ Press the “Calibrate” softkey to calibrate the Cable Prowler.
This will calibrate the Cable Prowler at 0 ft. No cables should
be connected to the Cable Prowler when performing a
calibration.
▪ Press the Save soft key to save your options.
Note: If only temporary change is desired, do not press
the save button. If the save button is not pressed, the
previous settings will be restored once the unit is pow-
ered off.
▪ To restore factory default values, press the defaults soft key.
▪ To view saved les, press the Files soft key.










