ParklandPlastics | Installation Instructions for PLAS-TEX NRP & PolyWall & Silk WATERPROOF WALL PANELS | 800-835-4110 | Manufacturers of bacteria and fungi r...
http://www.parklandplastics.com/install-nrp-polywall.shtml[7/25/2012 2:58:21 PM]
Parkland Panel Adhesive (Click here for installation instructions) 4.0+
Henry #444 FRP Panel Adhesive 4.0
SuperTek PanelSet FRP Panel Adhesive Available Through Parkland 4.0
Liquid Nails FRP #310 Panel Adhesive 3.5
NOT RECOMMENDED
Adhesives That Have Tested Poorly
Foster #97-37 by H.B. Fuller
*Parkland Panel Adhesive is the ONLY recommended adhesive, however the other adhesives listed
may give satisfactory results.
This technical bulletin is for the application of Parkland brand PLAS-TEX NRP and Poly-Wall wall panels under normal conditions of
installation. The recommendations provided in the bulletin represent our best judgement based on our experience with normal
applications. Information herein is offered without charge or obligation, and is accepted at recipient's sole risk. Because conditions
of use may vary and are beyond our knowledge and control, Parkland makes no representation about, and is not responsible or
liable for the accuracy or reliability of data, nor for toxicological effect or industrial hygiene requirements associated with
particular uses of any product or process describe herein. Parkland requests tat customers inspect and test our products before
use and satisfy themselves as to contents and suitability. Nothing herein shall constitute a warranty, expressed or implied,
including any warranty of merchantability or fitness, nor is protection from any law or patent inferred. All patent rights are
reserved. The exclusive remedy for all proven claims is replacement of Parkland materials.
Parkland™ Plastics, Inc. Copyright © 2012. All rights reserved.