User`s guide
19
FX-16NW
18
FX-16NW
Note:
Should you experience any problem in establishing a data link on any of
the ports, please refer to Appendix A and B for troubleshooting.
Be sure to use Category 5 UTP cables for 100BASE-TX connection.
S i m i l a r l y, use Category 3 (or greater) cables for 10BASE-T connection.
The maximum cable length is 100 meters.
The administrator can attach a PC to the serial console interface (RS-232
port) on the switching hub to configure and alter the default settings of
VLAN, Trunking, Spanning Tree Protocol as well as Port Mirroring features
of the product. This port is a DCE (data communication equipment) port
that utilizes a female DB-9 connector. A PC preinstalled with a terminal
utility is required to use the console port.
1. Configure your terminal utility in the following manner
Check each of the four parameters and change the value if necessary.
Baud Rate: 19,200 (default setting)
Parity: None
8 Data Bit
1 Stop Bit
2
6
Connecting a PC to the Console Port
4. Connect the other end of the cable to a port on the other device.
5. The Link LED of the port will be turned on when a valid link is
established.
6. To cascade more than two hubs to the FX-16NW, connect the uplink port
on the other hub to one of the ports (excluding the uplink port) on the
FX-16NW. If the other hub is not equipped with an uplink port, use a
crossover cable to connect the two hubs.
About Uplink port
An uplink port is used to connect to an additional hub, and its wires are
cross-linked inside the hub. If you are using Port 12 as an uplink port, be
sure to turn on (press down) the Uplink/Normal switch that is located right
next to Port 12. The following table shows valid port/ cable type
combinations
FX-16NW Cable Type The Other Hub
Uplink Port Straight RJ-45 Port
RJ-45 Port Straight Uplink Port
RJ-45 Port Crossover RJ-45 Port
Uplink Port Crossover Uplink Port
Figure 2-2