Datasheet

GS-4210-16UP4C
2
MSTP (Multiple Spanning Tree Protocol)
STP BPDU Guard, BPDU ltering and BPDU forwarding
Supports Link Aggregation
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
Cisco ether-channel (static trunk)
Provides port mirror (many-to-1)
Loop protection to avoid broadcast loops
Quality of Service
Ingress and egress rate limit per port bandwidth control
Storm control support
Broadcast/Unknown unicast/Unknown multicast
Trafc classication
IEEE 802.1p CoS
TOS/DSCP/IP precedence of IPv4/IPv6 packets
Strict priority and Weighted Round Robin (WRR) CoS policies
Multicast
Supports IPv4 IGMP snooping v2 and v3
Supports IPv6 MLD snooping v1, v2
IGMP querier mode support
IGMP snooping port ltering
MLD snooping port ltering
Security
Authentication
IEEE 802.1X port-based network access authentication
Built-in RADIUS client to cooperate with the RADIUS servers
RADIUS/TACACS+ login user access authentication
Access control list
IPv4/IPv6 IP-based ACL
MAC-based ACL
MAC security
Static MAC
MAC ltering
Port security for source MAC address entries ltering
DHCP snooping to lter distrusted DHCP messages
Dynamic ARP Inspection discards ARP packets with invalid
MAC address to IP address binding
IP source guard prevents IP spoong attacks
DoS attack prevention
SSH/SSL
Management
IPv4 and IPv6 dual stack management
Switch management interface
Web switch management
Telnet command line interface
SNMP v1, v2c and v3
SSH and SSL secure access
User privilege levels control
Wireless
AP/Router
PTZ
Camera
WiMAX
AP/CPE
IP Phone
Door
Phone
Thin
Client
IP Camera
Video
Phone
POS
System
Laptop
Digital
Signage
Built-in Unique PoE Functions for Powered Devices Management
As it is the managed PoE switch for surveillance, wireless and VoIP networks, the GS-
4210-16UP4C features the following special PoE management functions:
PD alive check
Scheduled power recycling
PoE schedule
PoE usage monitoring
Intelligent Powered Device Alive Check
The GS-4210-16UP4C can be configured to monitor connected PD (Powered Device)
status in real time via ping action. Once the PD stops working and responding, the GS-
4210-16UP4C will resume the PoE port power and bring the PD back to work. It will
greatly enhance the network reliability through the PoE port resetting the PD’s power
source and reducing administrator management burden.
PT PoE Camera
Ping Request
Ping Request
Check alive status for 3 times
Restart PoE device if without response
Ping Echo
No Response......
PD Alive!!
Step 1
Step 3
Step 2
Step 4
ON
PoE
ON
ON
PoE
OFF
PD Status
Good!!
Alarm Notification
Scheduled Power Recycling
The GS-4210-16UP4C allows each of the connected PoE IP cameras or PoE wireless
access points to reboot at a specified time each week. Therefore, it will reduce the
chance of IP camera or AP crash resulting from buffer overow.
S M T W T F S
Automatically Reboot
Every Friday 23:00
PoE PT Camera
ON ON
PoE
OFF
CPU/Buffer
Load 85%
CPU/Buffer
Load 10%