User Manual
User’s Manual of FGSD-1022 Series 
4.12.4 Misc Configuration 
In this page, you can change the default configuration for the 802.1x standard: 
Figure 4-12-6: 802.1x Misc Configuration interface 
The page includes the following fields: 
Object  Description 
Quiet Period: 
Used to define periods of time during which it will not attempt to acquire a 
supplicant. 
Default time is 60 seconds. 
TX Period: 
Set the period the port waits for retransmit next EAPOL PDU during an 
authentication session. 
Default value is 30 seconds. 
Supplicant Timeout: 
Set the period of time the switch waits for a supplicant response to an EAP 
request. 
Default value is 30 seconds. 
Server Timeout: 
Set the period of time the switch waits for a server response to an authentication 
request. 
Default value is 30 seconds. 
Max Requests: 
Set the number of authentication that must time-out before authentication fails 
and the authentication session ends. 
Default value is 2 times. 
Reauth period: 
Set the period of time which clients connected must be re-authenticated. 
Default value is 3600 seconds. 
137