User Manual
316
Users Manual of XGS-6350-24X4C
Step7 ethernet oam link-monitor
frame-seconds {threshold
{high { symbols |none} | low
{symbols}} | window
symbols}
Sets the high and low thresholds of the
second event of error frame, which triggers
the link events of error frame’s second.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 900 and its
default value is none.
The threshold low parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 900 and its
default value is 1.
The window parameter is used to configure
the window size of the round-query period.
Its unit is second. It ranges between 10 and
900 and its default value is 60.
Step8 ethernet oam link-monitor
receive-crc {threshold
{high { symbols |none} | low
{symbols}} | window
symbols}
Sets the high and low thresholds of the error
CRC frame event, which triggers the link
events of CRC checksum error.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 65535 and
its default value is none.
The threshold high parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 65535 and
its default value is 1.
The window parameter is used to configure
the window size of the round-query period.
Its unit is second. It ranges between 1 and
180 and its default value is 10.
Step9 ethernet link-monitor on
Enables the local link monitoring. When the
link monitoring function is supported, the
local link monitoring is automatically
enabled.
33.1.3.4 Configuring the Trouble Notification From Remote OAM Entity
You can configure an error-disable action on an interface. The local interface will enter the errdisabled state
in the following cases:
1. The high threshold of a normal link event on a local interface is exceeded.