User Manual
313
Users Manual of XGS-6350-24X4C
Procedure
Command Purpose
Step1 config
Enters the global configuration mode.
Step2 interface intf-type intf-id
Enters the interface configuration mode.
Step3 ethernet oam
Enables Ethernet OAM on an interface.
Step4 ethernet oam [max-rate
oampdus |
min-rate seconds | mode
{active | passive} | timeout
seconds]
Configures optional OAM parameters:
The max-rate parameter is used to
configure the maximum number of
OAMPDUs transmitted per second. It
ranges between 1 and 10 and its default
value is 10.
The min-rate parameter is used to
configure the minimum transmission
rate of OAMPDU. Its unit is second. It
ranges between 1 and 10 and its default
value is 1.
The mode {active | passive} parameter
is used to set the mode of OAM. The
OAM connection can be established
between two interfaces only when at
least one interface is in active mode.
The timeout parameter is used to set
the timeout time of the OAM connection.
It ranges between 1 and 30 seconds
and its default value is 1 second.
You can run no Ethernet oam to shut down the OAM function.
The remote OAM loopback cannot be enabled on the physical interface that belongs to the aggregation
interface.
33.1.3.2 Enabling Remote OAM Loopback
The procedure to enable remote loopback on an interface is shown in the following table:
Procedure
Command Purpose
Step1 config
Enters the global configuration mode.
Step2 interface intf-type intf-id
Enters the interface configuration mode.
Step3 ethernet oam
remote-loopback {supported
| timeout seconds}
Configures optional loopback parameters
from the remote OAM:
The supported parameter is used to
enable an interface to support the
remote loopback of Ethernet OAM.
Remote loopback is not supported by