User Manual

270
Users Manual of XGS-6350-24X4C
Switch_config_ring2#sub-ring
Switch_config_ring2#control-vlan 2
The following commands are used to set the time related parameters:
Switch_config_ring2#pre-forward-time 12
Exits from the node configuration mode:
Switch_config_ring2#quit
The following commands are used to set the transit port of node 2:
Switch_config#interface gigaEthernet 0/1
Switch_config_g0/1#mether-ring 2 domain 1 transit-port
Switch_config_g0/1#switchport mode trunk
Switch_config_g0/1#quit
Switch_config#interface gigaEthernet 0/2
Switch_config_g0/2#mether-ring 2 domain 1 transit-port
Switch_config_g0/2#switchport mode trunk
Switch_config_g0/2#quit
Configuring switch S2:
The following commands are used to set the major-ring transit node, node 1:
Switch_config#mether-ring 1 domain 1
Switch_config_ring1#transit-node
Switch_config_ring1#major-ring
Switch_config_ring1#control-vlan 2
The following commands are used to set the time related parameters:
Switch_config_ring1#pre-forward-time 12
Exits from the node configuration mode:
Switch_config_ring1#quit
The following commands are used to set the transit port of node 1:
Switch_config#interface gigaEthernet 0/1
Switch_config_g0/1#mether-ring 1 domain 1 transit-port
Switch_config_g0/1#switchport mode trunk
Switch_config_g0/1#quit
Switch_config#interface gigaEthernet 0/2
Switch_config_g0/2#mether-ring 1 domain 1 transit-port
Switch_config_g0/2#switchport mode trunk
Switch_config_g0/2#quit
The following commands are used to set the sub-ring edge node, node 2:
Switch_config#mether-ring 2 domain 1
Switch_config_ring2#edge-node
Switch_config_ring2#sub-ring (this can be omitted)