Step 4:
Enable TFTP server in the PC. Run TFTP server program. Before start downloading upgrade
file to the switch, verify the connectivity between the server and the switch by ping from the
switch. If ping succeeds, run “load” command in the BootROM mode from the switch; if it fails,
perform troubleshooting to find out the cause.
The following update file boot.rom. (This device only supports the upgrading of the boot file
under the BootROM mode.)
[Boot]: load boot.rom
TFTP from server 192.168.1.66; our IP address is 192.168.1.2
Filename 'boot.rom'.
Load address: 0x81000000
Loading: #################################################################
################################
done
Bytes transferred = 438700 (6b1ac hex)
[Boot]:
Step 5:
Execute write boot.rom in BootROM mode. The following saves the update file.
[Boot]: write boot.rom
File exists, overwrite? (Y/N)[N] y
Writing flash:/boot.rom......
Write flash:/boot.rom OK.
[Boot]:
Step 6:
After successful upgrade, execute run or reboot command in BootROM mode to return to CLI
configuration interface.
[Boot]: runor reboot
Other commands in BootROM mode
1. DIR command
Used to list existing files in the FLASH.
[Boot]: dir
Scanning JFFS2FS: , done.
-rw-r--r-- 2861 Thu Jan 01 03:45:31 1970 portal.cfg