74-17
be disabled the anti-ring function, otherwise, the detection may fail.
If there is port configured as truck port on this vsf (include port-channel port), please en
sure whether the vlan used for bfd mad detection is in this trunk (trunk port belongs to
all vlan as default). If it is in, the vlan used for bfd mad detection must be filtered under
this port, otherwise, the loop may appears.
If there is port configured as hybrid port on this vsf, please ensure that this hybrid port
does not belong the vlan used for bfd mad detection, otherwise, the loop may appears.
The vlan interface and all the ports in this vlan used for bfd mad detection cannot be co
nfigured other configuration except bfd mad detection.
If the bfd mad function will not be used any more, clear the configuration and the conne
ction line used for bfd mad should be removed.
If bfd mad configuration has been already completed, and other ports, vlan or the comm
and under the global mode should be modified, please ensure whether it conforms the a
bove items.
Suggestion: user should select a vlan which is not used in business on the whole as th
e specific vlan for bfd mad detection.