XGS-5240-Series User Manual
Table Of Contents
- Chapter 1 INTRODUCTION
- Chapter 2 INSTALLATION
- Chapter 3 witch Management
- Chapter 4 Basic Switch Configuration
- Chapter 5 File System Operations
- Chapter 6 Cluster Configuration
- Chapter 7 USB Function Configuration
- Chapter 8 Device Management
- Chapter 9 Port Configuration
- Chapter 10 Port Isolation Function Configuration
- Chapter 11 Port Loopback Detection Function Configuration
- Chapter 12 ULDP Function Configuration
- Chapter 13 LLDP Function Operation Configuration
- Chapter 14 Port Channel Configuration
- Chapter 15 MTU Configuration
- Chapter 16 bpdu-tunnel-protocol Configuration
- Chapter 17 DDM Configuration
- Chapter 18 EFM OAM Configuration
- Chapter 19 LLDP-MED
- Chapter 20 PORT SECURITY
- Chapter 21 QSFP+ Port Split and Combination Configuration
- Chapter 22 VLAN Configuration
- Chapter 23 MAC Table Configuration
- Chapter 24 MSTP Configuration
- Chapter 25 QoS Configuration
- Chapter 26 PBR Configuration
- Chapter 27 IPv6 PBR Configuration
- Chapter 28 Flow-based Redirection
- Chapter 29 Egress QoS Configuration
- Chapter 30 Flexible QinQ Configuration
- Chapter 31 Layer 3 Management Configuration
- Chapter 32 ARP Scanning Prevention Function Configuration
- Chapter 33 Prevent ARP, ND Spoofing Configuration
- Chapter 34 ARP GUARD Configuration
- Chapter 35 Gratuitous ARP Configuration
- Chapter 36 DHCP Configuration
- Chapter 37 DHCPv6 Configuration
- Chapter 38 DHCP option 82 Configuration
- Chapter 39 DHCPv6 option37, 38
- Chapter 40 DHCP Snooping Configuration
- Chapter 41 DHCP option 60 and option 43
- Chapter 42 IPv4 Multicast Protocol
- Chapter 43 IPv6 Multicast Protocol
- Chapter 44 Multicast VLAN
- Chapter 45 ACL Configuration
- Chapter 46 Self-defined ACL Configuration
- Chapter 47 802.1x Configuration
- 47.1 Introduction to 802.1x
- 47.2 802.1x Configuration Task List
- 47.3 802.1x Application Example
- 47.4 802.1x Troubleshooting
- Chapter 48 The Number Limitation Function of MAC and IP in Port, VLAN Configuration
- 48.1 Introduction to the Number Limitation Function of MAC and IP in Port, VLAN
- 48.2 The Number Limitation Function of MAC and IP in Port, VLAN Configuration Task Sequence
- 48.3 The Number Limitation Function of MAC and IP in Port, VLAN Typical Examples
- 48.4 The Number Limitation Function of MAC and IP in Port, VLAN Troubleshooting Help
- Chapter 49 Operational Configuration of AM Function
- Chapter 50 Security Feature Configuration
- 50.1 Introduction to Security Feature
- 50.2 Security Feature Configuration
- 50.2.1 Prevent IP Spoofing Function Configuration Task Sequence
- 50.2.2 Prevent TCP Unauthorized Label Attack Function Configuration Task Sequence
- 50.2.3 Anti Port Cheat Function Configuration Task Sequence
- 50.2.4 Prevent TCP Fragment Attack Function Configuration Task Sequence
- 50.2.5 Prevent ICMP Fragment Attack Function Configuration Task Sequence
- 50.3 Security Feature Example
- Chapter 51 TACACS+ Configuration
- Chapter 52 RADIUS Configuration
- Chapter 53 SSL Configuration
- Chapter 54 IPv6 Security RA Configuration
- Chapter 55 VLAN-ACL Configuration
- Chapter 56 MAB Configuration
- Chapter 57 PPPoE Intermediate Agent Configuration
- Chapter 58 SAVI Configuration
- Chapter 59 Captive Portal Authentication
- 59.1 Captive Portal Authentication Configuration
- 59.2 Accounting Function Configuration
- 59.3 Free-resource Configuration
- 59.4 Authentication White-list Configuration
- 59.5 Automatic Page Pushing after Successful Authentication (it is not supported currently)
- 59.6 http-redirect-filter
- 59.7 Portal Non-perception
- 59.8 Portal Escaping
- Chapter 60 VRRP Configuration
- Chapter 61 IPv6 VRRPv3 Configuration
- Chapter 62 MRPP Configuration
- Chapter 63 ULPP Configuration
- Chapter 64 ULSM Configuration
- Chapter 65 Mirror Configuration
- Chapter 66 RSPAN Configuration
- Chapter 67 SNTP Configuration
- Chapter 68 NTP Function Configuration
- Chapter 69 DNSv4/v6 Configuration
- Chapter 70 Summer Time Configuration
- Chapter 71 Monitor and Debug
- Chapter 72 Reload Switch after Specified Time
- Chapter 73 Debugging and Diagnosis for Packets Received and Sent by CPU
- Chapter 74 VSF
- Chapter 75 SWITCH OPERATION
- Chapter 76 TROUBLESHOOTING
- Chapter 77 APPENDIX A
- Chapter 78 GLOSSARY
Configuration Guide of XGS-5240-Series
74-16
74.4 VSF Troubleshooting
For VSF, under the configuration and usage, the command may not be workable, please pa
y attention to the following items:
Whether it is at the operation mode, because some of the commands can only be config
ured at VSF operation mode, but some of them can operation at both VSF and indepen
dent operation mode.
Under the failure of VSF during the VSF processes, or appear any abnormity, please pa
y attention to the following thing:
First, need to check whether physical connection is correct. Right now, the group VSF m
achine can only support million-mega port or logic port colligate. Please check whether t
he colligate port is the million-mega port.
Whether the Vsf member id is clash, if the member ids are clashing, the facilities cannot
form vsf.
Whether the Vsf domain numbers are same. Only the vsf domain numbers are identical,
the facilities can form the vsf.
To see whether the logical port has any physical connection, for example, double speed,
bandwidth restriction, safety authentication, ACL etc configuration.
Under the VSF operation mode to undergo configuration, please pay attention to the following thi
ngs:
During the VSF operation mode, VSF related configuration can be done on the each me
mber separately. However, the configuration done on the members cannot be saved inde
pendently. It cans still excute the write function on the vsf master. All the membes’ perso
nal configuration that is related to vsf will be save in the main computer’s vsf.cfg.
Under the VSF operation mode, some of the commands such as VSF domain number, p
riority of member, member id etc can still be configured or amended. After the configurati
on, the show run displays as the latest value, it can only be effective as you restart the
computer after saving.
Under the VSF operation mode, the active mode must be used for port group for ensuri
ng the fault convergence time.
For LACP MAD, under the configuration and usage, if there are problems, please pay atten
tion to the following items:
When creating the aggregation group, the aggregation of the device which is detected an
d the middle device must be identical.
The ports of the device which is detected and the middle device cannot be added into t
he aggregation with on mode for LACP MAD, one should be active method at least.
When the device which is detected and the middle device are both vsf, the domain id (v
sf domain number) of the two vsf cannot be the same.
For BFD MAD, under the configuration and usage, if there are problems, please pay attenti
on to the following items:
bfd mad function cannot be enabled under interface vlan 1.
bfd mad function and the anti-ring function are mutually exclusive (such as stp, mstp, et
c). if this vsf is configured anti-ring function, the ports used for bfd mad detection should