Configuration Guide of XGS-5240-Series
141
3. Compatibility verification
Compatibility verification is used to analyze whether the environment of the module
accords the data manual or it is compatible with the corresponding standard, because the
module capability is able to be ensured only in the compatible environment. Sometimes,
environment parameters exceed the data manual or the corresponding standard, it will make
the falling of the module capability that result in the transmission error.
Environment is not compatible with the module are as below:
1Voltage exceeds the set range
2Rx power is overload or is under the sensitivity of the transceiver
3Temperature exceeds the range of the running temperature
17.1.2 DDM Function
DDM descriptions are shown in the following:
1. Show the monitoring information of the transceiver
Administrator is able to know the current working state of the transceiver and find some
potential problems through checking the real-time parameters (including TX power, RX power,
Temperature, Voltage, Bias current) and querying the monitoring information (such as warning,
alarm, real-time state and threshold, and so on). Besides, checking the fault information of the
fiber module helps administrator to fast locate the link fault and saves the restored time.
2. Threshold defined by the user
For real-time parameters (TX power, RX power, Temperature, Voltage, Bias current),
there are fixed thresholds. Because the users environments are difference, the users is able
to define the threshold (including high alarm, low alarm, high warn, low warn) to flexibly
monitor the working state of the transceiver and find the fault directly.
The thresholds configured by the user and the manufacturer can be shown at the same
time. When the threshold defined by the user is irrational, it will prompt the user and
automatically process alarm or warning according to the default threshold. (the user is able to
restore all thresholds to the default thresholds or restore a threshold to the default threshold)
Threshold rationality: high/low warn should be between high alarm and low alarm and
high threshold should be higher than low threshold, namely, high alarm>= high warn>= low
warn>= low alarm.
For fiber module, verification mode of the receiving power includes inner verification and
outer verification which are decided by the manufacturer. Besides the verification mode of the
real-time parameters and the default thresholds are same.
3. Transceiver monitoring
Besides checking the real-time working state of the transceiver, the user needs to monitor
the detailed status, such as the former abnormity time and the abnormity type. Transceiver
monitoring helps the user to find the former abnormity status through checking the log and