User's Manual

Table Of Contents
Configuration Guide of XGS-5240-Series
60-31
(1) Configure the preemptive mode for VRRP
Command
Explanation
VRRP protocol configuration mode
preempt-mode {true| false}
Configures the preemptive mode for VRR
P.
(2) Configure VRRP priority
Command
Explanation
VRRP protocol configuration mode
priority <priority>
Configures VRRP priority.
(3) Configure VRRP Timer intervals
Command
Explanation
VRRP protocol configuration mode
advertisement-interval <time>
Configures VRRP timer value (in second
s).
(4) Configure VRRP interface monitor
Command
Explanation
VRRP protocol configuration mode
circuit-failover {IFNAME | Vlan <ID> }
<value_reduced>
no circuit-failover
Configures VRRP interface monitor, the "
no circuit-failover" removes monitor to t
he interface.
60.3 VRRP Typical Examples
As shown in the figure below, SwitchA and SwitchB are Layer three Ethernet Switc
hes in the same group and provide redundancy for each other.