WGSW-Series (V3) User Manual

Table Of Contents
Users Manual of WGSW-24040 and 24040HP Series Managed switch
39
MGB-TLA10(V2)
MGB-
TLB10(V2)
YES
1000 WDM(LC) Single Mode 10km 1310nm 1550nm
-40 ~ 75
1000 WDM(LC) Single Mode 10km 1550nm 1310nm
-40 ~ 75
MGB-TLA20
MGB-TLB20
YES
1000 WDM(LC) Single Mode 20km 1310nm 1550nm
-40 ~ 75
1000 WDM(LC) Single Mode 20km 1550nm 1310nm
-40 ~ 75
MGB-TLA40
MGB-TLB40
YES
1000 WDM(LC) Single Mode 40km 1310nm 1550nm
-40 ~ 75
1000 WDM(LC) Single Mode 40km 1550nm 1310nm
-40 ~ 75
MGB-TLA80
MGB-TLB80
YES
1000 WDM(LC) Single Mode 80km 1490nm 1550nm
-40 ~ 75
1000 WDM(LC) Single Mode 80km 1550nm 1490nm
-40 ~ 75
It is recommended to use PLANET SFP/SFP+ on the Managed Switch. If you insert an SFP/SFP+
transceiver that is not supported, the Managed Switch will not recognize it.
Before connecting the other Managed Switches, workstation or Media Converter.
1. Make sure both sides of the SFP transceiver are with the same media type, for example, 1000BASE-SX to 1000BASE-SX,
1000BASE-LX to 1000BASE-LX.
2. Check whether the fiber-optic cable type matches the SFP transceiver model.
To connect to 1000BASE-SX SFP transceiver, use the multi-mode fiber cable -- with one side being male duplex LC
connector type.
To connect to 1000BASE-LX SFP transceiver, use the single-mode fiber cable -- with one side being male duplex LC
connector type.
Connecting the fiber cable
1. Attach the duplex LC connector on the network cable to the SFP transceiver.
2. Connect the other end of the cable to a device switches with SFP installed, fiber NIC on a workstation or a media
converter.
3. Check the LNK/ACT LED of the SFP slot on the front of the Managed Switch. Ensure that the SFP transceiver is operating
correctly.
4. Check the Link mode of the SFP port if the link fails. It works with some fiber-NICs or media converters and sets the link
mode to 1000 Force” or “100 Forcewhen needed.
Removing the transceiver module
1. Make sure there is no network activity by checking with the network administrator. Or through the management interface
of the switch/converter (if available), disable the port in advance.
2. Remove the fiber optic cable gently.
3. Turn the lever of the MGB module to a horizontal position.
4. Pull out the module gently through the lever.