4.16.10 PoE Alive Check Configuration
The WGS-5225 PoE Switch can be configured to monitor connected PDs status in real-time via ping action. Once the PD stops
working and without response, the WGS-5225 PoE Switch is going to restart PoE port port power, and bring the PD back to
work. It will greatly enhance the reliability and reduces administrator management burden.
This page provides you with how to configure PD Alive Check.The screen in Figure 4-16-10 appears.
Figure 4-16-10: PD Alive Check Configuration Screenshot
The page includes the following fields:
Object Description
Mode
Allows user to enable or disable per port PD Alive Check function.
As default value all ports are disabled.
Ping PD IP Address
This coulumn allows user to set PoE device IP address here for system making ping
to the PoE device. Please note that the PDs IP address must be set to the same