User's Manual

Table Of Contents
User’s Manual of WGS Managed Series
Delta: Calculate the difference between samples.
Risin
g threshold value (0–2147483647)
Rising Threshold
Fallin
g threshold value (0–2147483647)
Falling Threshold
Event to fire
when the rising threshold is crossed
Rising Event
Event to fire
when the falling threshold is crossed
Falling Event
S
pecify an owner for the alarm
Owner
Buttons
: Click to apply changes.
Figure 4-14-6 RMON Alarm Status Page Screenshot
The page includes the following fields:
Object Description
Indicates th
e index of Alarm control entry
Index
Displ
ay the current sample port
Sample Port
Displ
ay the current sample variable
Sample Variable
Displ
ay the current interval
Sample Interval
Displ
ay the current sample type
Sample Type
Displ
ay the current rising threshold
Rising Threshold
Displ
ay the current falling threshold
Falling Threshold
Displ
ay the current rising event
Rising Event
Displ
ay the current falling event
Falling Event
Displ
ay the current owner
Owner
Action
Click
to delete RMON alarm entry
329