User Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web Page
- 4.2 System
- 4.3 Port Management
- 4.4 Link Aggregation
- 4.5 VLAN
- 4.5.1 VLAN Overview
- 4.5.2 IEEE 802.1Q VLAN
- 4.5.3 Management VLAN
- 4.5.4 Create VLAN
- 4.5.5 Interface Settings
- 4.5.6 Port to VLAN
- 4.5.7 Port VLAN Membership
- 4.5.8 Protocol VLAN Group Setting
- 4.5.9 Protocol VLAN Port Setting
- 4.5.10 GVRP Setting
- 4.5.11 GVRP Port Setting
- 4.5.12 GVRP VLAN
- 4.5.13 GVRP Statistics
- 4.5.14 VLAN setting example:
- 4.6 Spanning Tree Protocol
- 4.7 Multicast
- 4.8 Quality of Service
- 4.9 Security
- 4.10 ACL
- 4.11 MAC Address Table
- 4.12 LLDP
- 4.13 Diagnostics
- 4.14 RMON
- 4.15 Power over Ethernet
- 4.16 Maintenance
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A Switch's RJ45 Pin Assignments
User’s Manual of WGS Managed Series
PoE Schedule for Energy Saving
Under the trend of energy saving worldwide and contributing to environmental protection, the WGS PoE managed series can
effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to
enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs
or enterprises save power and money. It also increases security by powering off PDs that should not be in use during
non-business hours.
PoE Usage Monitoring
Via the power usage chart in the web management interface, the WGS PoE managed series enables the administrator to
monitor the status of the power usage of the connected PDs in real time. Thus, it greatly enhances the management efficiency
of the facilities.
Flexibility and Extension Solution
The WGS-4215-8T2S provides two dual-speed fiber SFP slots, it can also connect with the 100BASE-FX / 1000Base-SX/LX
SFP (Small Form-factor Pluggable) fiber transceiver and then to backbone switch and monitoring center over a long distance.
The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and up to 10/20/30/40/50/70/120 kilometers
(single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.
Intelligent SFP Diagnosis Mechanism
The WGS-4215-8T2S supports SFP-DDM (Digital Diagnostic Monitor) function that greatly helps network administrator to
easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias
current and transceiver supply voltage.
14