User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G TABLE OF CONTENTS 1. INTRODUCTION ....................................................................................... 5 1.1 PACKAGE CONTENTS ..................................................................................................... 5 1.2 PRODUCT DESCRIPTION ................................................................................................. 6 1.3 HOW TO USE THIS MANUAL...............................................................
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.6 Configuration Setting ........................................................................................ 36 4.3.7 Factory Default ................................................................................................. 38 4.3.8 System Log ...................................................................................................... 40 4.3.9 System Reboot ............................................................................
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1. INTRODUCTION Thank you for purchasing PLANET 8-/16-/24-Port Gigabit 60W Ultra PoE Managed Injector Hub, UPOE-800G/UPOE-1600G/UPOE-2400G. The description of this series is shown below: UPOE-800G 8-Port Gigabit 60W Ultra PoE Managed Injector Hub (400 watts) UPOE-1600G 16-Port Gigabit 60W Ultra PoE Managed Injector Hub (600 watts) UPOE-2400G 24-Port Gigabit 60W Ultra PoE Managed Injector Hub (800 watts) 1.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1.2 Product Description PLANET Ultra PoE Managed Injector Hub series, a cost-effective and quick Ultra PoE solution, is designed to perfectly upgrade an existing network infrastructure to Ultra Power over Ethernet network system without replacing the existing Ethernet Switch.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G device. It possesses double amount of power capability than the conventional 802.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Built-in Unique PoE Functions for Powered Device Management As it is the Ultra PoE Managed Injector Hub for VoIP, wireless and surveillance networks, the Ultra PoE Managed Injector Hub features the following special PoE management functions: PoE schedule PD alive check Scheduled power recycling UPOE, end-span or mid-span selectable in PoE power output mode PoE usage monitoring Over temperature protection 8
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Intelligent Powered Device Alive Check PLANET’s Managed PoE products adopt not only Power over Ethernet technology, but also automated PD monitoring and real-time PoE status. The Ultra PoE Managed Injector Hub can be configured to monitor connected PD’s status in real time via ping action through the uplinked Ethernet switch.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Advanced PoE Power Output Mode Management To fulfill the demand of various powered devices consuming stable PoE power, the Ultra PoE Managed Injector Hub provides three different PoE power output modes for selection.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Intelligent LED Indicator for Real-time PoE Usage The Ultra PoE Managed Injector Hub helps users to monitor the current status of PoE power usage easily and efficiently by its advanced LED indication. The front panel of the UPOE-800G has four green LEDs indicating 100W, 200W, 300W and 400W of PoE power usage. The front panel of the UPOE-1600G also has four green LEDs indicating 150W, 300W, 450W and 600W of PoE power usage.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1.3 How to Use This Manual This User Manual is structured as follows: Section 2, Installation It explains the functions of Ultra PoE Managed Injector Hub and how to physically install the Ultra PoE Managed Injector Hub. Section 3, Management It contains information about the software function of the Ultra PoE Managed Injector Hub. Section 4, Web Configuration The section explains how to manage the Ultra PoE Managed Injector Hub through Web interface.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1.4 Product Features Interface UPOE-800G Complies with the IEEE 802.3, IEEE 802.3u and IEEE 802.3ab Ethernet standards 16-port RJ45 8-port 10/100/1000Mbps “Data input” 8-port 10/100/1000Mbps “Data + Power output” One 10/100/1000BASE-T management port UPOE-1600G Complies with the IEEE 802.3, IEEE 802.3u and IEEE 802.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G PD classification detection Over temperature protection PD alive check PoE schedule Management Web interface for remote management Supports Network Time Protocol (NTP) Firmware upgrade through Web interface PLANET Smart Discovery utility automatically finds PLANET devices on the network SNMP trap for alarm notification of events System log/remote syslog Hardware 19-inch rack mountable; 1U height Reset button for resetting to de
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Management Management Interface Web, PLANET Smart Discovery Lite Power limit by consumption and allocation PoE admin mode Per port power schedule Per port power enable/disable Power feeding priority PoE Management Over temperature protection Current per port usage and status Total power consumption PD alive check Scheduled power recycling Setup of system/management functions Management Feature Web firmware upgrade SNMP trap for alarm notification of event
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 2. INSTALLATION This section describes the hardware features and installation of Ultra PoE Managed Injector Hub on the desktop or rack mount. For easier management and control of the Ultra PoE Managed Injector Hub, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before deploying the Ultra PoE Managed Injector Hub, please read this chapter completely. 2.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G The following is the summary table of reset button functions: Reset Button Pressed and Released About 5 second Function Reboot the Ultra PoE Managed Injector Hub. Reset the Ultra PoE Managed Injector Hub to Factory Default configuration. The Ultra PoE Managed Injector Hub will reboot About 10 seconds and load the default IP settings.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G UPOE-1600G ■ System LED Color Function SYS Power Green PoE Fail Red Lights to indicate PoE module failure. FAN1 Fail Red Lights to indicate FAN1 stops. FAN2 Fail Red Lights to indicate FAN2 stops. 1000 Green 10/100 Orange Lights to indicate power on. Lights to indicate management port is working on 1000Mbps Ethernet speed. Lights to indicate management port is working on 10/100Mbps Ethernet speed.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 2.1.3 Injector Rear Panel The rear panel of the Ultra PoE Managed Injector Hub indicates an AC inlet power socket, which accepts input power from 100 to 240V AC, 50/60Hz. Figures 2-1-5 & 2-1-6 shows the rear panel of the Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Figure 2-2-1: Desktop Installation of the Ultra PoE Managed Injector Hub When choosing a location, please keep in mind the environmental restrictions discussed in Chapter 1, Section 5, under Specifications. Step 4: Connect your Ultra PoE Managed Injector Hub to network 60W/802.3at/802.3af powered devices (PD) and Switch. A.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Figure 2-2-2: Brackets attaching to the Ultra PoE Managed Injector Hub You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate the warranty. Step 3: Secure the brackets tightly. Step 4: Follow the same steps to attach the second bracket to the opposite side.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 2.2.3 Network Application Installation The Ultra PoE Managed Injector Hub is not an equipment with data switching function between data ports. To inject PoE power and transmit data packets to PDs, the Ultra PoE Managed Injector Hub is usually linked to an Ethernet switch. Typically, the Ultra PoE Injector is installed between regular Ethernet switch and PDs, and mostly it is located close to the Ethernet switch side.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 2.2.4 Power over Ethernet Powered Device Voice over IP phones 3~5 watts Enterprise can install PoE VoIP Phone, ATA and other Ethernet/non-Ethernet end-devices in the central area where UPS is installed for un-interruptible power system and power control system. Wireless LAN Access Points Museums, sightseeing spots, airports, hotels, campuses, factories, and warehouses can install the Access Point anywhere.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 3 MANAGEMENT This chapter describes how to manage the Ultra PoE Managed Injector Hub with the following topics included: - Overview - Management Method - Logging on to the Ultra PoE Managed Injector Hub 3.1 Overview The Ultra PoE Managed Injector Hub provides a user-friendly, Web interface where you can perform various device configuration and management activities, including: System SNMP Power over Ethernet 3.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 3.3 Management Method User can manage the Ultra PoE Managed Injector Hub by Web Management via a network connection. 3.3.1 Web Management The Ultra PoE Managed Injector Hub can be configured through an Ethernet connection. The factory default IP address is 192.168.0.100 with subnet mask 255.255.255.0, so please make sure the manager PC must be set to the same IP subnet address.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1. For security reason, please change and memorize the new password after this first setup. 2. Only accept command in lowercase letter under Web interface. 3.3.2 PLANET Smart Discovery Utility For easily listing the Ultra PoE Managed Injector Hub in your Ethernet environment, Planet Smart Discovery Utility from user’s manual CD-ROM is an ideal solution. The following installation instructions guide you to running Planet Smart Discovery Utility.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 1. Press the “Refresh” button for the currently-connected devices in the discovery list and the screen is shown as follows: Figure 3-1-4: Planet Smart Discovery Utility Screen This utility shows all necessary information from the devices, such as MAC address, device name, firmware version and device IP subnet address. It can also assign new password, IP subnet address and description of the devices.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4 WEB CONFIGURATION The Ultra PoE Managed Injector Hub provides Web interface for PoE smart function configuration and makes the Ultra PoE Managed Injector Hub operate more effectively. They can be configured through the Web browser. A network administrator can manage and monitor the Ultra PoE Managed Injector Hub from the local LAN. This section indicates how to configure the Ultra PoE Managed Injector Hub to enable its smart function.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.2 Web Panel At the top of the Web management page, the active panel displays the link status of management port and PoE ports. Figure 4-2-1: Web Panel Screen Green light indicates network data is sending or receiving. Orange light indicates the PoE is in use. 4.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G • Firmware Upgrade Allow to upgrade the latest firmware in the future. Explained in section 4.3.5. • Configuration Setting Allow to back up or restore system configuration. Explained in section 4.3.6. • Factory Default Allow to reset system to factory default setting. Explained in section 4.3.7. Allow to enable system log and to record system log. Explained in section 4.3.8. • System Log • System Reboot Allow to reboot system. Explained in section 4.3.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.2 IP Configuration This section provides the IP Configuration of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-2 appears. Table 4-3-2 describes the IP Configuration object of Ultra PoE Managed Injector Hub. Figure 4-3-2: IP Configuration Web Page Screen Object Description • DHCP Client Allows to disable or enable the DHCP Client function of Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.3 NTP Configuration This section provides the NTP Configuration of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-3 appears and Table 4-3-3 describes the NTP Configuration object of Ultra PoE Managed Injector Hub. Figure4-3-3: NTP Configuration Web Page Screen Object Description • Current Time Allow input current time information of Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.4 Password Setting This section provides the Password Setting of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-4 appears. Table 4-3-4 describes the Password Setting objects of Ultra PoE Managed Injector Hub. Figure 4-3-4: Password Setting Web Page Screen Object Description • User Name Allows to input current User Name of Ultra PoE Managed Injector Hub. • Old Password Allows to input current Password of Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.5 Firmware Upgrade This section provides the firmware upgrade of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-5 appears. Figure 4-3-5: Firmware Upgrade Web Page Screen Please press “Browse” to locate the latest firmware of Ultra PoE Managed Injector Hub that deposits in your PC. The screen in Figure 4-3-6 appears.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.6 Configuration Setting This function allows output the current Ultra PoE Managed Injector Hub configuration as a file, and upload it to other Ultra PoE Managed Injector Hub for quick multi-devices setting. The description of the procedure and screens in the following appears. The screen in Figure 4-3-8 appears and Table 4-3-5 describes the Configuration Setting object of Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Figure 4-3-10: File Save Screen ■ Configuration Upload Click the “Browse” button of the Configuration Setting Web page and the system would pop up the file selection screen to choose saved configuration. The screen in Figure 4-3-11 appears.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Select on the configuration file and then click “Upload”. After system has uploaded, the screen in Figure 4-3-12 appears. Figure 4-3-12: Configuration Upload Finished Screen When configuration has been uploaded, please re-login the system. Figure 4-3-13: System Login Screen 4.3.7 Factory Default This section describes resetting the Ultra PoE Managed Injector Hub to factory default mode; the screen appears in Figure 4-3-14.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Please press the “Reset” button to take effect and the “Do you really want to reset the current settings to default?” popup window appears. Please press the “OK” button to continue the factory default process. The screen appears in Figure 4-3-15. Figure 4-3-15: Factory Default Web Page Screen Then the reboot screen appears in Figure 4-3-16 and please wait for 60 seconds for rebooting the Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.8 System Log This section provides the system log setting and information display of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-18 appears. Table 4-3-6 describes the system log setting object of Ultra PoE Managed Injector Hub. Figure 4-3-18: System Log Web Page Screen Object Description • Enable Log Disable or enable the system log function of Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.9 System Reboot This section provides the system reboot function of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-19 appears. Figure 4-3-19: System Reboot Web Page Screen Press the “Reboot” button to reboot the Ultra PoE Managed Injector Hub as the screen in Figure 4-3-20 appears Figure 4-3-20: System Reboot Web Page Screen Wait for 60 seconds for completing the reboot process of Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.3.10 Logout This section provides logout function of Ultra PoE Managed Injector Hub as the screen in Figure 4-3-21 appears. Figure 4-3-21: Logout Web Page Screen Press the “Logout” button and then the popup window with re-login request appears as the screen in Figure 4-3-22 appears.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Figure 4-3-23: Main Web Page Screen 43
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.4 SNMP The Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. It is part of the Transmission Control Protocol/Internet Protocol (TCP/IP) protocol suit. SNMP enables network administrations to manage network performance, find and solve network problems, and plan for network growth. The SNMP provides SNMP Management and SNMP Trap as shown in Figure 4-4-1.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Object Description • SNMP Agent Disable or enable the SNMP Agent function of Ultra PoE Managed Injector Hub. • SNMP Read Community Allow to input characters for SNMP Read Community of Ultra PoE Managed Injector Hub. The maximum length is 30 characters. • SNMP Write Community Allows to input characters for SNMP Write Community of Ultra PoE Managed Injector Hub. The maximum length is 30 characters.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.5 Power over Ethernet Power Management: In a Power over Ethernet system, operating power is applied from a power source (PSU-power supply unit) over the LAN infrastructure to powered devices (PDs), which are connected to ports. Under some conditions, the total output power required by PDs can exceed the maximum available power provided by the PSU.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.5.1 PoE Configuration This section provides PoE (Power over Ethernet) Configuration and PoE output status of Ultra PoE Managed Injector Hub as screen in Figure 4-5-2 appears. Table 4-5-2 describes the PoE Configuration object of Ultra PoE Managed Injector Hub. Figure 4-5-2: PoE Configuration Web Page Screen Object Description • System PoE Admin Mode Allows user to disable / enable PoE function. • Power Supply Displays PoE power supply status.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G • Power Allocation Displays the current total power consumption status. This function provides input per port description and the available letters is 30. • Description NOTE: The total maximum letters are only 800. Some of special words will count as 5 per word, like ‘, “, \, < and >. • PoE Function Allows user to disable or enable per port PoE function, also allow choose schedule for enable PoE Schedule function of each port.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.5.2 PoE Schedule Profile This section provides user to configure PoE schedule and scheduled power recycling. The “PoE schedule” helps you to enable or disable PoE power feeding for PoE ports during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money. Scheduled Power Recycling The Ultra PoE Managed Injector Hub allows each of the connected PoE IP cameras to reboot at a specified time each week.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G The PoE Schedule Profile Web Screens are shown in Figure 4-5-3 and Table 4-5-3. Figure 4-5-3: PoE Configuration Web Page Screen The page includes the following information: Object Description • PoE Function Allows user to disable or enable per port PoE function, also allow choose schedule for enable PoE Schedule function of each port. Indicates the scheduled profile mode.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G PoE Schedule user can configure a duration time for PoE port as default value does not provide power; screen in Figure 4-5-4 and Table 4-5-4 show. Figure 4-5-4: PoE Schedule Web Page Screen The page includes the following information: Object Description Set the schedule profile mode. Possible profiles are: Profile1 • Profile Profile2 Profile3 Profile4 • Delete Check to delete the entry.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G • Start Hour Allows user to set what hour PoE function does by enabling it. • Start Min Allows user to set what minute PoE function does by enabling it. • End Hour Allows user to set what hour PoE function does by disabling it. • End Min Allows user to set what minute PoE function does by disabling it. • Reboot Enable Allows user to enable or disable the whole PoE port reboot by PoE reboot schedule.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.5.3 PoE Alive Check Configuration The Ultra PoE Managed Injector Hub can be configured to monitor connected PD’s status in real-time via ping action. Once the PD stops working and without response, the Ultra PoE Managed Injector Hub are going to restart PoE port power, and bring the PD back to work. It will greatly enhance the reliability and reduces administrator management burden.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G The page includes the following fields: Object Description • Mode Allows user to enable or disable per port PD Alive Check function. All ports are disabled as default value. • Remote PD IP Address This column allows user to set PoE device IP address here for system making ping to the PoE device. Please note that the PD’s IP address must be set to the same network segment as the Ultra PoE Managed Injector Hub.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 4.5.4 PoE Status This page allows user to see the usage of individual PoE Port. The screen in Figure 4-5-6 appears Figure 4-5-6: PoE Status Screenshot The page includes the following fields: Object Description • Port Number Displays per port status. • Watt Displays per port PoE usage. • Indicates the end-span PoE operation mode of that port. • Indicates the mid-span PoE operation mode of that port.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 5. POWER OVER ETHERNET OVERVIEW What is PoE? Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethernet, the most widely installed local area network technology adopted today. PoE allows the electrical power necessary for the operation of each end-device to be carried by data cables rather than by separate power cords.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G Figure 5-1-1 - Power Supplied over the Spare Pins The data pairs are used. Since Ethernet pairs are transformer coupled at each end, it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer. In this mode of operation the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 6. THE POE PROVISION PROCESS While adding PoE support to networked devices is relatively painless, it should be realized that power cannot simply be transferred over existing Cat5e cables. Without proper preparation, doing so may result in damage to devices that are not designed to support provision of power over their network interfaces. The PSE is the manager of the PoE process.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G 6.3 Start-up Once line detection and optional classification stages are completed, the PSE must switch from low voltage to its full voltage capacity (44-57 Volts) over a minimal amount of time (above 15 microseconds). A gradual startup is required, as a sudden rise in voltage (reaching high frequencies) would introduce noise on the data lines.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G APPENDIX A A.1 MDI Settings The Medium-Dependent Interface (MDI or RJ45) serves as the data/power interface between Ethernet elements. As such, it has two optional connection methods to carry the power. Named Alternative A & B, Table 1 details the two power feeding alternatives.
User’s Manual of UPOE-800G/UPOE-1600G/UPOE-2400G A.3 DATA OUT PoE Injector RJ45 Port Pin Assignments PIN NO 10BASE-T 1000BASE-T 100BASE-TX 1 TX+ DC- DA+ DC- 2 TX- DC- DA- DC- 3 RX+ DC+ DB+ DC+ 4 - DC+ DC+ DC+ 5 - DC+ DC- DC+ 6 RX- DC+ DB- DC+ 7 - DC- DD+ DC- 8 - DC0 DD- DC0 A.4 RJ45 Pin Assignment of Non-802.3af/802.3at Standard PD with PoE Mid-span PD Pin out of Cisco non-802.