Industrial Layer 3 Managed TSN Switch TSN-6325-8T4S4X Quick Installation Guide
Table of Contents 1. Package Contents....................................................................... 3 2. Requirements............................................................................. 4 3. Wiring the Power Inputs............................................................. 5 3.1 Grounding the Device........................................................... 6 4. Terminal Setup........................................................................... 7 4.1 Logging on to the Console.....
1. Package Contents Thank you for purchasing PLANET L3 Industrial Managed TSN Switch, TSN-6325-8T4S4X. “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the above model. Open the box of the Industrial Managed Switch and carefully unpack it.
2. Requirements The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management: • Workstations running Windows XP/2003/2008/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP Protocols. • Workstations are installed with Ethernet NIC (Network Interface Card). • Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-toRS232 converter.
3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector within 6 contacts. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2. DC 9-48V, AC 24V DI0 DI1 DO0 DO1 GND GND 1 2 3 4 5 6 Max.
3.1 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device. DI0 DI1 DO0 DO1 GND GND 1 2 3 4 5 6 Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 V1+ PWR1 V2+ Alarm DC Input: 9-48V AC Input: 24V PWR2 , 5A max. , 2A max.
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. TSN Industrial Managed Switch PC/Workstation with Terminal Emulation Software Ring R.O. I/O RJ45 to DB9 RS232 Cable Console 115200,N,8,1 Reset Console Port 115200,N,8,1 Serial Port A terminal program is required to make the software connected to the Industrial Managed Switch. 1. Run terminal program on the OS. 2.
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows as the login screen in Figure 4-1 appears. Username: admin Password: admin Figure 4-1: Console Login Screen The user can now enter commands to manage the Industrial Managed Switch.
4.2 Configuring IP Address via Console The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows: Display of the Current IP Address 1. At the “#” prompt, enter “show ip interface brief”. TSN-6325-8T4S4X # show ip interface brief 2. The screen displays the current IP address shown in Figure 4-2.
Configuration of the IP Address 3. At the “#” prompt, enter the following command and press as shown in Figure 4-3. TSN-6325-8T4S4X# configure terminal TSN-6325-8T4S4X (config)# interface vlan 1 TSN-6325-8T4S4X (config-if-vlan)# ip address 192.168.1.100 255.255.255.0 The previous command would apply the following settings for the Industrial Managed Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Figure 4-3: Configuring IP Address Screen 4.
4.3 Storing Current Switch Configuration 1. At the “#” prompt, enter the following command and press . # copy running-config startup-config Figure 4-4: Saving Current Configuration Command Screen If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address.
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
5.1 Logging in to the Industrial Managed Switch 1. Use Chrome 98.0.xxx or above for Web browser and enter IP address https://192.168.0.100 (the factory-default IP address) to access the Web interface. 2. When the following dialog box appears, please enter the default user name “admin” and password “admin” (or the password you have changed before) as shown in Figure 5-2. Default IP Address: 192.168.0.
3. After entering the password, the main screen appears as shown in Figure 5-3. Figure 5-3: Web Main Screen of Industrial Managed Switch The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “Ring” and “Maintenance”.
Figure 5-6: Switch Sub-menu Now, you can use the Web management interface to continue the Switch management. Please refer to the user manual for more. Note If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description. 5.2 Saving Configuration via Web To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot. 1.
2. Press the “Save Configuration” button. 3. Or the other way to save the setting is to Click Maintenance, Save Startup Config.
6. Recovering Back to Default Configuration IP address has been changed or admin password has been forgotten – To reset the IP address to the default IP address “192.168.0.100” and the user password to factory default mode (default password is admin), press the hardware-based reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx and default password.
7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw TSN-6325-8T4S4X User’s Manual: https://www.planet.com.