User's Manual

Table Of Contents
78-20
faulty: PD detection failed
deny: not enough available power or the required power is over the limit
Power
The power used by the port currently
Max
The max power allowed to be distributed to the port
Current
The present current of the port
Volt
The present voltage of the port
Priority The Power supply priority
Critical: the highest-level priority
High: the high-level priority
Low: the low-level priority
Class Class Usage PD Input Power (W)
0 Default 0.44~12.95
1 Optional 0.44~3.84
2 Optional 3.84~6.49
3 Optional 6.49~12.95
4 Reserved treated as class 0 and reserved for future use
It is impossible for a compatible PD to provide a class 4 signal
Examples:
Display the current PoE status on port 1 to port 6.
Switch# show power inline interface ethernet 1/0/1-6
Interface Status Oper Power(mW) Max(mW) Current(mA) Volt(V) Priority Class
------------ ------- ------ --------- ------- ----------- ------- -------- -----
Ethernet1/0/1 enable off 0 15400 0 0 high 0
Ethernet1/0/2 enable off 0 15400 0 0 low 0
Ethernet1/0/3 enable off 0 15400 0 0 low 0
Ethernet1/0/4 enable off 0 15400 0 0 low 0
Ethernet1/0/5 enable off 0 15400 0 0 low 0
Ethernet1/0/6 enable off 0 15400 0 0 low 0
78.2.1.3 debug power inline
Command:
debug power inline
no debug power inline
Function:
Enable or disable the PoE debugging.