SGS-6341-Series User Manual

Table Of Contents
4-12
{<num-std>|<name>}] [ipv6-access
{<ipv6-num-std>|<ipv6-name>}]
no snmp-server user <user-string>
[access {<num-std>|<name>}]
[ipv6-access
{<ipv6-num-std>|<ipv6-name>}]
6. Configure group
Command Explanation
Global Mode
snmp-server group <group-string>
{noauthnopriv|authnopriv|authpriv} [[read
<read-string>] [write <write-string>] [notify
<notify-string>]] [access
{<num-std>|<name>}] [ipv6-access
{<ipv6-num-std>|<ipv6-name>}]
no snmp-server group <group-string>
{noauthnopriv|authnopriv|authpriv}
[access {<num-std>|<name>}]
[ipv6-access
{<ipv6-num-std>|<ipv6-name>}]
Set the group information on the switch. This
command is used to configure VACM for
SNMP v3.
7. Configure view
Command Explanation
Global Mode
snmp-server view <view-string>
<oid-string> {include|exclude}
no snmp-server view <view-string>
[<oid-string>]
Configure view on the switch. This command
is used for SNMP v3.
8. Configuring TRAP
Command Explanation
Global Mode
snmp-server enable traps
no snmp-server enable traps
Enable the switch to send Trap message.
This command is used for SNMP v1/v2/v3.
snmp-server host { <host-ipv4-address> |
Set the host IPv4/IPv6 address which is used
User’s Manual of SGS-6341 series