SGS-6341-Series User Manual

Table Of Contents
17-65
PortDesc :Ethernet1/1
SysName :****
SysDesc :*****
SysCapSupported :4
SysCapEnabled :4
Explanation:
1) Both Ethernet2 of switch A and Ethernet1 of switch B are the ports of network connection
device, they will not send LLDP packets with MED TLV information forwardly. Although
configure Ethernet1 of switch B to send MED TLV information, it will not send the related MED
information, that results the corresponding Remote table without the related MDE information
on Ethernet2 of switch A.
2) LLDP-MED device is able to send LLDP packets with MED TLV forwardly, so the
corresponding Remote table with LLDP MED information on Ethernet1 of switch A.
17.4 LLDP-MED Troubleshooting
If problems occur when configuring LLDP-MED, please check whether the problem is caused
by the following reasons:
Check whether the global LLDP is enabled.
Only network connection device received LLDP packets with LLDP-MED TLV from
the near MED device, it sends LLDP-MED TLV. If network connection device
configured the command for sending LLDP-MED TLV, the packets also without
LLDP-MED TLV sent by the port, that means no MED information is received and
the port does not enable the function for sending LLDP-MED information.
If neighbor device has sent LLDP-MED information to network connection device,
but there is no LLDP-MED information by checking show lldp neighbors command,
that means LLDP-MED information sent by neighbor is error.