SGS-6341-Series User Manual

Table Of Contents
16-59
Diagnostic Threshold
Realtime Value High Alarm Low Alarm High Warn Low Warn
------------ ----------- ----------- ------------ ---------
Temperature(℃) 33 70 0 70 0
VoltageV 7.31 10.00 0.00 5.00 0.00
Bias currentmA 3.11 10.30 0.00 5.00 0.00
RX PowerdBM -30.54(A-) 9.00 -25.00(-34) 9.00 -25.00
TX PowerdBM -1.01 9.00 -12.05 9.00 -10.00
Ethernet 1/22 transceiver threshold-violation information:
Transceiver monitor is disabled. Monitor interval is set to 30 minutes.
The last threshold-violation doesn’t exist.
16.4 DDM Troubleshooting
If problems occur when configuring DDM, please check whether the problem is caused by the
following reasons:
Ensure that the transceiver of the fiber module has been inserted fast on the port, or
else DDM configuration will not be shown.
Ensure that SNMP configuration is valid, or else the warning event cannot inform the
network management system.
Because only some boards and box switches support SFP with DDM or XFP with
DDM, ensure the used board and switch support the corresponding function.
When using show transceiver command or show transceiver detail command, it
cost much time due to the switch will check all ports, so it is recommended to query
the monitoring information of the transceiver on the specified port.
Ensure the threshold defined by the user is valid. When any threshold is error, the
transceiver will give an alarm according to the default setting automatically.
User’s Manual of SGS-6341 series