SGS-6341-Series User Manual

Table Of Contents
16-55
4Clear the information of the transceiver monitoring
Command Explanation
Admin Mode
clear transceiver threshold-violation [interface
ethernet <interface-list>]
Clear the threshold violation of the
transceiver monitor.
16.3 Examples of DDM
Example1:
Ethernet 21 and Ethernet 23 are inserted the fiber module with DDM, Ethernet 24 is inserted
the fiber module without DDM, Ethernet 22 does not insert any fiber module, show the DDM
information of the fiber module.
aShow the information of all interfaces which can read the real-time parameters normally,(No
fiber module is inserted or the fiber module is not supported, the information will not be shown),
for example:
Switch#show transceiver
Interface Temp(℃) VoltageV BiasmA RX PowerdBM TX Power
dBM
1/21 33 3.31 6.11 -30.54(A-) -6.01
1/23 33 5.00W+ 6.11 -20.54(W-) -6.02
bShow the information of the specified interface. (N/A means no fiber module is inserted or
does not support the fiber module), for example:
Switch#show transceiver interface ethernet 1/21-22;23
Interface Temp(℃) VoltageV BiasmA RX PowerdBM TX PowerdBM
1/21 33 3.31 6.11 -30.54(A-) -6.01
1/22 N/A N/A N/A N/A N/A
1/23 33 5.00W+ 6.11 -20.54(W-) -6.02
cShow the detailed information, including base information, parameter value of the real-time
monitoring, warning, alarm, abnormity state and threshold information, for example:
Switch#show transceiver interface ethernet 1/21-22;24 detail
Ethernet 1/21 transceiver detail information:
Base information:
User’s Manual of SGS-6341 series