SGS-6341-Series User Manual

Table Of Contents
14-44
restores the default value.
ethernet-oam timeout <seconds>
no ethernet-oam timeout
Configure timeout of EFM OAM
connection, no command restores
the default value.
2. Configur
e link monitor
Command Explanation
Port Mode
ethernet-oam link-monitor
no ethernet-oam link-monitor
Enable link monitor of EFM OAM, no
command disables link monitor.
ethernet-oam errored-symbol-period
{threshold low <low-symbols> | window
<seconds>}
no ethernet-oam errored-symbol-period
{threshold low | window }
Configure the low threshold and
window period of errored symbol
period event, no command restores
the default value. (optional)
ethernet-oam errored-frame-period {threshold
low <low-frames> | window <seconds>}
no ethernet-oam errored-frame-period
{threshold low | window }
Configure the low threshold and
window period of errored frame
period event, no command restores
the default value.
ethernet-oam errored-frame {threshold low
<low-frames> | window <seconds>}
no ethernet-oam errored-frame {threshold low
| window }
Configure the low threshold and
window period of errored frame
event, no command restores the
default value. (optional)
ethernet-oam errored-frame-seconds
{threshold low <low-frame-seconds> | window
<seconds>}
no ethernet-oam errored-frame-seconds
{threshold low | window }
Configure the low threshold and
window period of errored frame
seconds event, no command
restores the default value. (optional)
User’s Manual of SGS-6341 series