User's Manual

Table Of Contents
Configuration Guide of SGS-6341-Series
2-40
10Gbps SFP+ (10G Ethernet/10GBASE)
Model Speed (Mbps)
Connector
Interface
Fiber Mode Distance Wavelength (nm)
Operating Temp.
MTB-SR
10G
LC
Multi Mode
Up to 300m
850nm
0 ~ 60 degrees C
MTB-LR 10G
LC
Single Mode 10km 1310nm 0 ~ 60 degrees C
10Gbps SFP+ (10GBASE-BX, Single Fiber Bi-directional SFP)
Model
Speed
(Mbps)
Connector
Interface
Fiber Mode
Distance
Wavelength
(TX)
Wavelength
(RX)
Operating Temp.
MTB-LA20
MTB-LB20
10G
WDM(LC)
Single Mode
20km
1270nm
1330nm
0 ~ 60 degrees C
10G
WDM(LC)
Single Mode
20km
1330nm
1270nm
0 ~ 60 degrees C
MTB-LA40
MTB-LB40
10G
WDM(LC)
Single Mode
40km
1270nm
1330nm
0 ~ 60 degrees C
10G
WDM(LC) Single Mode 40km 1330nm 1270nm
0 ~ 60 degrees C
MTB-LA60
MTB-LB60
10G
WDM(LC)
Single Mode
60km
1270nm
1330nm
0 ~ 60 degrees C
10G
WDM(LC)
Single Mode
60km
1330nm
1270nm
0 ~ 60 degrees C
It is recommended to use PLANET SFP/SFP+ on the Managed Switch. If you insert an
SFP/SFP+ transceiver that is not supported, the Managed Switch will not recognize it.
1. Before we connect the SGS-6341 series to the other network device, we have to make sure both sides
of the SFP transceivers are with the same media type, for example: 1000BASE-SX to 1000BASE-SX,
1000Bas-LX to 1000BASE-LX.
2. Check whether the fiber-optic cable type matches with the SFP transceiver requirement.
To connect to 1000BASE-SX SFP transceiver, please use the multi-mode fiber cable with one side
being the male duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, please use the single-mode fiber cable with one side
being the male duplex LC connector type.
Connect the Fiber Cable
1. Insert the duplex LC connector into the SFP/SFP+ transceiver.
2. Connect the other end of the cable to a device with SFP/SFP+ transceiver installed.
3. Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the Managed Switch. Ensure that the
SFP/SFP+ transceiver is operating correctly.
4. Check the Link mode of the SFP/SFP+ port if the link fails. To function with some fiber-NICs or Media
Converters, user has to set the port Link mode to 10G Force, 1000M Forceor 100M Force”.
Remove the Transceiver Module
1. Make sure there is no network activity anymore.
2. Remove the Fiber-Optic Cable gently.
3. Lift up the lever of the MGB module and turn it to a horizontal position.
4. Pull out the module gently through the lever.