User's Manual

Table Of Contents
Users Manual of SGS-5240 Series Managed Switch
273
4.8.7.12 Show Local MEP
Device Management > CFM > Show Local MEP page is used to show information for the MEPs configured on this device.
MEP ID Maintenance end point identifier.
MD Name Maintenance domain name.
Level Authorized maintenance level for this domain.
Direction Direction in which the MEP communicates CFM messages:
Down indicates that the MEP is facing away from the switch, and transmits CFM messages towards, and receives
them from, the direction of the physical medium.
Up indicates that the MEP faces inward toward the switch cross connect matrix, and transmits CFM messages
towards, and receives them from, the direction of the internal bridge relay mechanism.
Primary VLAN Service VLAN ID.
Interface Physical interface of this entry (either a port or trunk).
CC Status Shows administrative status of CCMs.
MAC Address MAC address of this MEP entry.
4.8.7.13 Show Local MEP Details
Device Management > CFM > Show Local MEP Details page is used to show detailed CFM information about a local MEP in
the continuity check database.
MD Index Domain index. (Range: 1-65535)
MA Index MA identifier. (Range: 1-2147483647)
MEP ID Maintenance end point identifier. (Range: 1-8191)
MD Name The maintenance domain for this entry.
MA Name Maintenance association to which this remote MEP belongs.
MA Name Format The format of the Maintenance Association name, including primary VID, character string, unsigned
Integer 16, or RFC 2865 VPN ID.
Level Maintenance level of the local maintenance point.
Direction The direction in which the MEP faces on the Bridge port (up or down).
Interface The port to which this MEP is attached.
CC Status Shows if the MEP will generate CCM messages.
MAC Address MAC address of the local maintenance point. (If a CCM for the specified remote MEP has never been