Alarm: It means system will issue an alarm message via Syslog, SMTP.
Reboot Time (30~180s)
This column allows user to set the PoE device rebooting time. As there are so many
kinds of PoE devices on the market, they have different rebooting times. The PD
Alive-check is not a defining standard, so the PoE device on the market doesn’t
report reboots done information to the HPOE-1200G/HPOE-2400G PoE switch. So
user has to make sure how long the PD will be finished to boot, and then set the
time value to this column.
System is going to check the PD again according to the reboot time. If you cannot
make sure precise booting time, we suggest you set it longer.
Buttons
: Click it to save changes.
: Click it to reset configuration which doesn’t have to be saved yet.