User Manual

User’s Manual of POE-1200G / POE-2400G / HPOE-1200G / HPOE-2400G
Reset button
At the left of the front panel, the reset button is designed for rebooting the PoE Injector Hub without turning off and on
the power.
Hardware
Reset Button
Figure 2-1-5: Reset Button of PoE Injector Hub
The following is the summary table of reset button functions:
Reset Button Pressed and Released Function
About 1 second Reboot the PoE Injector Hub.
About 8 seconds
Reset the PoE Injector Hub to Factory Default configuration.
The PoE Injector Hub will reboot and load the default IP
settings as shown below.
Be sure that you back up the current configuration of PoE Injector Hub before resetting PoE
Injector Hub or else the entire configuration will be erased when pressing the “RESET” button.
2.1.2 LED Indicators
The front panel LEDs indicate instant status of system power, management port Link/Active and PoE port links, thus
helping administrator to monitor and troubleshoot when needed.
POE-1200G / HPOE-1200G
LED Color Function
SYS Power Green Lights to indicate power on.
PoE Failure Red Lights to indicate PoE module failure.
Fan Failure Red Lights to indicate fans have stopped.
PoE-in-use Green Lights to indicate that the port is in use and supplying 52V DC power.
Green Lights to indicate the link through that port is successfully established at 1000Mbps.
Management
Port
Orange Lights to indicate the link through that port is successfully established at 10/100Mbps.
15