Figure 5-62 2
Step 3: Select the Alarm Output number, Delay time, Alarm Name and Alarm
Status.
Step 4: Set the Arming Schedule.
Step 5: Click "Apply" to save the setting.
Copy: Click "Copy" to apply the alarm output port settings to other
alarm output ports.
Trigger: Click "Trigger" to start the alarm corresponding to the device
connected to the alarm output port. The alarm output device connected to
the current channel will alarm.