by a time interval. This event is generated if the number of errored frame
seconds is equal to or greater than the specified threshold for that period. An
errored frame second is a one second interval wherein at least one frame error
was detected. Errored frames are frames that had transmission errors as
detected at the Media Access Control sublayer. Error Window for 'Seconds
Summary Event' must be an integer value between 10-900 and its default value
is '60'. Whereas Error Threshold must be between 0-65535 and its default value
is '1'.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
4.3.14.6 MIB Retrieval
This page allows you to configure Link OAM MIB Retrieval, as screen in Figure 4-3-14-6 appears.
Figure 4-3-14-6: MIB Retrieval Page Screenshot