User's Manual

Table Of Contents
Users Manual of MGSD-10080F
254
One-Way
If true, one way measurements are used.
This parameter applies only to a slave. In one-way mode no delay
measurements are performed, i.e. this is applicable only if frequency
synchronization is needed.
The master always responds to delay requests.
2 Step Flag
Static member: defined by the system, true if two-step Sync events and
Pdelay_Resp events are used
Ports
The total number of physical ports in the node
Clock Identity
It shows unique clock identifier
Dom
Clock domain [0..127].
Clock Quality
The clock quality is determined by the system, and holds 3 parts: Clock Class,
Clock Accuracy and OffsetScaledLog Variance as defined in IEEE1588.
The Clock Accuracy values are defined in IEEE1588 table 6 (Currently the clock
Accuracy is set to 'Unknown' as default).
Pri1
Clock priority 1 [0..255] used by the BMC master select algorithm.
Pri2
Clock priority 2 [0..255] used by the BMC master select algorithm.
Local Prio
Priority [1..255] used in the 8275.1 BMCA.
Protocol
Transport protocol used by the PTP protocol engine
Ethernet PTP over Ethernet multicast
EthernetMixed PTP using a combination of Ethernet multicast and
unicast
IPv4Multi PTP over IPv4 multicast
IPv4Mixed PTP using a combination of IPv4 multicast and unicast
IPv4Uni PTP over IPv4 unicast
VID
VLAN Identifier used for tagging the VLAN packets.
PCP
Priority Code Point value used for PTP frames.
DSCP
DSCP value used when transmitting IPv4 encapsulated packets