User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 ARP Table
- 4.2.1.5 Users Configuration
- 4.2.1.6 Privilege Levels
- 4.2.1.7 NTP Configuration
- 4.2.1.7.1 System Time Correction Manually
- 4.2.1.8 Time Configuration
- 4.2.1.9 UPnP
- 4.2.1.10 DHCP Relay
- 4.2.1.11 DHCP Relay Statistics
- 4.2.1.12 CPU Load
- 4.2.1.13 System Log
- 4.2.1.14 Detailed Log
- 4.2.1.15 Remote Syslog
- 4.2.1.16 SMTP Configuration
- 4.2.1.17 Fault Alarm
- 4.2.1.18 Digital Input/Output
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.5 Remote Management
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Private VLAN
- 4.3.3.7 Port Isolation
- 4.3.3.8 VLAN setting example:
- 4.3.3.9 MAC-based VLAN
- 4.3.3.10 IP Subnet-based VLAN Membership Configuration
- 4.3.3.11 Protocol-based VLAN
- 4.3.3.12 Protocol-based VLAN Membership
- 4.3.2.13 VLAN Translation
- 4.3.4 Spanning Tree Protocol
- 4.3.5 Multicast
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.3.13 PTP
- 4.3.14 Link OAM
- 4.4 Quality of Service
- 4.4.2 Bandwidth Control
- 4.4.4.2 DSCP-based QoS
- 4.5 Security
- 4.6 Ring
- 4.7 Maintenance
- 5. COMMAND LINE MODE
- 6. SWITCH OPERATION
- 7. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of MGSD-10080F
20
1.5 Product Specifications
Product MGSD-10080F
Hardware Specifications
SFP Fiber Optic Ports
6 1000BASE-SX/LX/BX SFP interfaces, from port 1 to port 6
Compatible with 100BASE-FX SFP.
2 100/1000/2500BASE-X SFP interfaces, from port 7 to port 8
Copper Ports
2 10/ 100/1000BASE-T RJ45 auto-MDI/MDI-X ports (Port-9 and Port-10)
Console 1 x RJ45 serial port (115200, 8, N, 1)
Reset Button
< 5 sec: System reboot
> 5 sec: Factory default
Power Requirements
AC 100~240V, 50/60Hz 0.15A
-36V DC @ 0.3A, Range: -36V ~ -60V DC
Power Consumption
Max. 11.2 watts/38.2 BTU (AC input)
Max. 10.8 watts/36.9 BTU (DC input)
Alarm
One relay output for power failure. Alarm Relay current carry ability: 1A @ DC 24V
DI/DO
2 Digital Input (DI): Level 0: -24V~2.1V (±0.1V)
Level 1: 2.1V~24V (±0.1V)
Input Load to 24V DC, 10mA max.
2 Digital Output (DO): Open collector to 24VDC, 100mA max.
ESD Protection
6KV DC
Dimensions (W x D x H)
330 x 155 x 43.5 mm, 1U high
Weight
1661g
LED
System:
PWR (Green)
DC 1 (Green)
DC 2 (Green)
Fault Alarm (Green)
Ring (Green)
Ring Owner (Green)
Per Gigabit SFP Ports: Port 1 to Port 6.
100 LNK/ACT (Orange)
1G LNK/ACT (Green)
Per Gigabit SFP Ports: Port 7 to Port 8.
100 LNK/ACT (Orange)
1G/2.5G LNK/ACT (Green)
Per Gigabit RJ45 Ports: Port 9 to Port 10.
10/100 LNK/ACT (Orange)
1G LNK/ACT (Green)
Switching
Switch Architecture Store-and-Forward
Switch Fabric
26Gbps/non-blocking
Throughput (packet per second)
19.3Mpps @ 64Bytes packet
Address Table 8K entries, automatic source address learning and aging
SDRAM
256Mbits