Managed Metro Ethernet Switch MGSW/MGSD/MGS Series Quick Installation Guide
Table of Contents 1. Package Contents........................................................................................ 3 2. Requirements.............................................................................................. 4 3. Wiring the Power Inputs............................................................................... 5 4. Terminal Setup............................................................................................ 7 4.1 Logging in to Console..........................
1. Package Contents Thank you for purchasing PLANET L3 and L2+ Managed Metro Ethernet Switches. The descriptions of these models are shown below: MGSD-10080F L2+ 6-Port 100/1000X SFP + 2-Port 1G/2.5G SFP + 2-Port 10/100/1000T Managed Metro Ethernet Switch MGS-6320-2T6S2X L3 2-Port 100/1000T + 2-Port 100/1000X SFP + 4-Port 2.
2. Requirements zz Workstations running Windows XP/2003/2008/2012/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. zz Workstations are installed with Ethernet NIC (Network Interface Card) zz Serial Port Connection (Terminal) The above workstations come with COM port (DB9) or USB-to-RS232 converter. The above workstations have been installed with terminal emulator, such as Tera Term, PuTTY or Hyper Terminal included in Windows XP/2003.
3. Wiring the Power Inputs The Front Panel of the Managed Metro Switch indicates a DC inlet power socket and consists of one terminal block connector within 6 contacts. Please follow the steps below to insert the power wire. MGSD-10080F Front Panel ON 100-240V , 0.2A max. CAUTION DC POWER ON 2 Please refer to user’s manual before connect the DC wire. 100/1G AC POWER DI 0 DI 1 DO 0 DO 1 GND GND Max. Fault Alarm Loading: 24V, 1A 4 6 8 10 DC 1 R.O.
Tighten the wire-clamp screws for preventing the wires from loosening. 1 2 V1+ V1- Power 1 Managed Metro Switch Note 6 3 4 5 6 V2+ V2- Power 2 Positive (+) Pin Negative (-) Pin Pin 1 / 5 Pin 2 / 6 The wire gauge for the terminal block should be in the range from 12 to 24 AWG.
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to the DB9 type of serial port of the Managed Metro Switch. PC / Workstation with Terminal Emulation Software Managed Switch RS232 to RJ45 Cable Serial Port RJ45 Console Port Figure 4-1: Managed Metro Switch Console Connectivity A terminal program, such as Tera Term or PuTTY, is required to make the software connection to the Managed Metro Switch. 1. Run terminal program on the OS. 2.
4.1 Logging in to Console Once the terminal is connected to the device, power on the Managed Metro Switch, and the terminal will display “running testing procedures”. Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows and the login screen in Figure 4-3 appears. Username: admin Password: admin Figure 4-3: Managed Metro Switch Console Login Screen The user can now enter commands to manage the Managed Metro Switch.
4.2 Configuring IP Address The Managed Metro Switch is shipped with default IP address shown below. IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedures as follows: Showing the Current IP Address 1. At the “#” prompt, enter “show ip interface brief”. 2. The screen displays the current IP address as shown in Figure 4-4. Figure 4-4: IP Information Screen Configuring IP Address 3.
The previous command would apply the following settings for the Managed Metro Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 4. Repeat step 1 to check if the IP address has changed. If the IP is successfully configured, the Managed Metro Switch will apply the new IP address setting immediately. You can access the Web interface of the Managed Metro Switch through the new IP address. 4.
5. Starting Web Management The following shows how to start up the Web Management of the Managed Metro Switch. Note the Managed Metro Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Managed Metro Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Default IP Address: 192.168.0.100 Default Username: admin Default Password: admin Figure 5-2: Login Screen 3. After entering the password, the main screen appears as Figure 5-3 shows.
The Switch Menu on the top of the Web page lets you access all the commands and statistics the Managed Metro Switch provides. The Switch Menu always contains one or more buttons, such as “Refresh”, “Save”, “Help” and “Logout”. Figure 5-4: Switch Menu Figure 5-5: Switch Menu–System Note If you are not familiar with Switch functions or the related parameter, press “Help icon” anytime on the Web page to get the help description.
5.2 Saving Configuration To save all applied changes and set the current configuration as a startup configuration on the Web user interface, the startup-configuration file will be loaded automatically across a system reboot. 1. Click the Save icon on the top Switch Menu bar. 2. Press the “Save Configuration” button. 3. Or the other way to save the setting is to Click Maintenance, Save Startup Config.
6. Recovering Back to Default Configuration IP address has been changed or admin password has been forgotten – To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the hardware-based reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xxx. 100-240V ON , 0.2A max.
7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw MGSW/MGSD series User’s Manual: https://www.planet.com.