Buttons
Auto-refres
h :
Check this
box to
refresh the
page
automatica
lly.
:
Click to
refresh the
page
immediatel
y.
(switch) on the ring.
Level
MD/MEG Level of R-APS PDUs we transmit.
Control VLAN
The VLAN on which R-APS PDUs are transmitted and received on the ring ports.
Control PCP
The PCP value used in the VLAN tag of the R-APS PDUs.
Rev
Revertive (true) or Non-revertive (false) mode.
Guard
Guard time in ms. Valid range is 10 - 2000 ms.
WTR
"Wait-to-Restore time in seconds. Valid range 1 - 720 sec.
Hold Off
Hold off time in ms. Value is rounded down to 100ms precision. Valid range is 0
- 10000 ms.
Enable
The administrative state of this APS ERPS. Check to make it function normally
and uncheck to make it cease functioning.
Oper
The operational state of ERPS instance.
: Active
: Disabled or Internal error.
Warning
Operational warnings of ERPS instance.
: No warnings
: There are warnings, use tooltip to see.
Configuration Buttons
You can modify each ERPS in the table using the following buttons:
: Edits the ERPS row.
: Deletes the ERPS.
: Adds new ERPS.